OPERATION
Speed Scrub 2601 Cylindrical Brush (06--06)
15
The electrolyte level (A) should slightly cover the
battery plates (B). Add distilled water as needed.
DO NOT OVERFILL, the fluid may expand and
overflow while charging. Replace cell caps before
charging (Figure 28).
A
B
FIG. 28
3. Connect the charger’s AC power supply cord to a
properly grounded receptacle (Figure 29).
Grounded
3 Hole Outlet
Ground Pin
FIG. 29
4. Plug charger’s DC output connector to battery
connector located near battery compartment
(Figure 30).
FIG. 30
5. The charger will automatically begin charging and
shut off when fully charged.
6. Rest the recovery tank on the support stand to
promote ventilation during charging (Figure 31).
FIG. 31
ATTENTION: Do not disconnect the charger’s DC
cord from the machine’s receptacle when the
charger is operating. Arcing may result. If the
charger must be interrupted during charging,
disconnect the AC power supply cord first.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
7. After charging, check the electrolyte level (A)
again. The level should be approximately
0.38 in / 1 cm from the bottom of the fill--port (B)
(Figure 32). Add distilled water if needed.
DO NOT OVERFILL.
A
B
FIG. 32