background image

EXPLODED VIEW

13

12

11

9

10

5

7

6

14

8

3

1

2

4

12

11

2

ITEM 

NO.

PART NAME

DRG NUMBER

LENGTH

Default/QT

Y.

1

S1C Frame

S1C

Default

9

2

CB1 Bracket

CB1

Default

8

3

JF1 Bracket

JF1

Default

12

4

ST3 Roof Tie

ST3

Default

1

5

P1 Post

P1

Default

1

6

FT1 Bracket

FT1

Default

3

7

FT3 Bracket

FT3

Default

8

8

RB1 Bracket

RB1

Default

16

9

R2 Rafter

R2

Default

5

10 Sealing Strip -  2195mm

Sealing Strip

Default

8

11

ACE2 Roof Panel

Default

2

12

ACC2 Roof Panel

Default

2

13

RC2 Roof Strip

Default

5

14

A2 Angle

A2

Default

8

15

40x40 End cap

BOUGHT IN ITEM

40 x 40 x 20

13

Summary of Contents for SR1563-F

Page 1: ...Assembly Instructions Shelter type SR1563 F SR1563 F 02 100119 USA...

Page 2: ...EXPLODED VIEW 13 12 11 9 10 5 7 6 14 8 3 1 2 4 12 11 2...

Page 3: ...x 78 74 1 6 FT1 Foot Bracket 109 x 100 x 40 4 29 x 3 93 x 1 57 3 7 FT3 Foot Bracket 109 x 100 x 80 4 29 x 3 93 x 3 27 8 8 RB1 Bracket 110 x 46 4 33 x 1 81 16 9 R2 Rafter 2200 x 40 x 40 87 40 x 40 55 5...

Page 4: ...equired Drill Screwdriver Mallet Hack saw Spanner Torx bit Bolt set M10 Nut Washer Black Cap T25 AB1210 M10 x 60 mm 25 mm Tech screw M10 12 x 100mm Concrete Bolt Pack C D 40 40 80 80 202 13 Required 2...

Page 5: ...CB1 CB1 CB1 Ensure correct alignment on corners Step 1 Assemble S1C frames to make up the main structure using CB1 brackets for the corners and JF1 brackets for the straight joints 5 MEASUREMENTS IN B...

Page 6: ...post using one JF1 bracket then attach ST3 tie bar using another JF1 bracket and two CB1 brackets Move the shelter to its final position make sure the structure is square and attach the FT1 and FT3 f...

Page 7: ...R2 RB1 R2 RB1 40 75 40 75 40 75 40 75 1035 1035 1035 1035 FRONT VIEW Step 3 Use RB1 brackets to secure the R2 roof rafters 7...

Page 8: ...pply sealing strips SS to the top of the rafters Align ACE2 roof panels with the outer rafters then space out the ACC2 panels evenly Cover the two edges along the outer rafters and gaps with RC2 strip...

Page 9: ...A2 Angle A2 Angle Step 5 Fit the square end caps EC40 to any open ends of box sections Screw A2 roof angles onto the edges of the roof as shown below 9...

Page 10: ...035 1035 985 50 985 50 995 2048 50 1035 985 50 1035 1035 2180 33 40 75 40 75 80 65 39 17 38 80 40 75 38 80 40 75 40 75 40 75 38 80 161 04 85 84 164 57 10 Plan view Suggested size for concrete base 200...

Page 11: ...11 NOTES...

Page 12: ...anels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales nobutts com Web www nobutts...

Reviews: