3. SENSOR CALIBRATION
Every
nke
sensor is adjusted at the factory. However, a calibration is required to adapt the
sensor to the specificities of your boat and to obtain an optimum measurement accuracy. Follow
the calibration procedure below, by visualising the settings on a display.
Please refer to the installation notice of the
TOPLINE
sensor that you wish to calibrate.
3.1 Setting procedure of the calibration coefficient
Example: setting the calibration coefficient of the
boat speed
channel at the value
1.1
.
Using the
Page
key,
select the
Main menu
page,
then using the browser, select
Configuration
then
calibration
,
press the
Ent
key,
in the list of channels, select
boat speed
, press the
Ent
key,
select
calibration
then press the
Ent
key,
using the browser, set the cursor of the calibration coefficient at
1.1
,
validate your setting by pressing the
Ent
key, or exit by pressing the
Page
key
CAUTION:
The
air
temperature
and
sea
temperature
channels have a distinctive feature. To cancel
the alarm of this channel, enter the value
0,
when the unit is the degree Fahrenheit, or
-
17.7,
when the unit is the degree Celsius. Enter the value in the upper alarm and the lower
alarm.
boat speed
Cancel : PAGE Validate: ENT
0.00 10
1.1
calibration
Calibration
depth
sea temperature
bus voltage
boat speed
validate : ENT Menu: PAGE
boat speed
Init
Calibration
Offset
To return to the menu
press page
Menu: configuration
Calibration Ent
Channels masking Ent
Languages Ent
Address initialisation Ent
NMEA initialisation Ent
NMEA console Ent
Ower code Ent
Pilot initialisation Ent