NKB PL2125 User Manual Download Page 22

 

22 

While  enter  the  dome  limit  setting  menu,  move  the  dome  to  the  suitable  position,  and 

press

Enter

to save and will show “Success" and back to previous menu. 

Select the item 2 to set the Right limit, and do the same as the left limit setting, 

Back to the menu and press

3

to operate the Run Scan 

Attention

 

 

 

 

4.2.3 Pattern 

Enter the menu as the Figure (4.1.1-1) 

Press

2

  enter the dome setting menu as the Figure 

4.2.1-1)

 

And then press

3

  enter the pattern setting as Figure 4.2.3-1 

 

 

                                                               

           

  Figure 4.2.3-1 

 

After  enter  the  menu,  the  system  need  input  the  pattern  information  you  want,  you 

can put in the Pattern ID (ID range base on the PTZ speed dome you use) and press the 

ENTER

to  confirm.  The  cursor  will  skip  to  the  next  item  to  set  the  PATTERN 

information. If you already have it, you can skip it and select the 

3

  to run the pattern 

directly. 

Pattern setting

After enter the pattern setting menu, move the dome do the suitable 

position  and  press  the 

1

  to  start  record  the  pattern  information.  The  screen  will 

display“Start ……

as the Figure 4.2.3-

2.    Press“0 ” to finish the pattern record, and the 

screen will show“Success” and back to the previous menu. 

 

 

 

                                                                 

           

  Figure 4.2.3-2

 

Attention:

 

 

 

 

Remark: While you want to run the PATTERN, you must set the STOP TIME and Speed in 

each PRESET. Otherwise this function will not working. 

4.2.4 Tour set up 

Press

2

  enter the dome setting menu, as the Figure 4.2.1-1 show, 

And then press

4

enter the tour setting as the Figure 4.2.4-1 show. 

 

 

 

Figure 4.2.4-1 

While  enter the  dome  SCAN  menu, the  keyboard  navigate keyboard  can  directly  control  the dome;  And  the  lens 

control zone (Iris, Focus, zoom) also work available; And in other menu situation, normally the operation is NULL.

 

1. Pattern num:     

2. Set pattern 

3. Run pattern 

Press 1 to start 

Press 0 to start 

Press PREV to back 

While  enter  the  dome  PATTERN  menu,  the  keyboard  navigate  keyboard  can  directly  control  the  dome;  And  the  lens 

control zone (Iris, Focus, zoom) also work available; And in other menu situation, normally the operation is NULL.

 

1. Tour num:       

2. Insert preset 

3. Run tour 

Summary of Contents for PL2125

Page 1: ...ual before using and take care of it properly It is a great honor to have you as our customers In order to help you master the know how of this multi functional keyboard as soon as possible here parti...

Page 2: ...eep it safely User s notice PL2125 multi functional keyboard is electronic equipment The potential safety risk may exist in the power line and the power adapter as well as any other components Any mis...

Page 3: ...supply lines power adapter and relevant battery accessories are not allowed Over operating load for power supply may arise to unstable voltage damaging the NKB keyboard controller item data and perip...

Page 4: ...the camera ID 16 3 7 Adjust the PTZ speed dome lens 16 3 8 PTZ Speed Dome function operation 16 3 8 1 Preset 16 3 8 2 Scan 16 3 8 3 Pattern 16 3 8 4 Tour 17 3 9 Call the main menu 17 3 10 Control the...

Page 5: ...r Menu 24 6 Using the internet 25 6 1Wired connection 25 6 2WIFI connection 25 7 Appendix 25 7 1 RS485 bus general knowledge 25 7 2 Controller shortcut instruction 28 8 Appendix B 29 8 1 System softwa...

Page 6: ...otocol products Can control the camera aperture size focus distance magnification Can set and call the ball s preset point level scanning and pattern scanning and tour Can control matrix and through t...

Page 7: ...nt to use the keyboard rocker to control monitoring equipment VGA input interface is used for taking the keyboard as a display device The keyboard can insert equipments with VGA output like PC host an...

Page 8: ...485 A B interface Dome cameras made by different manufacturers may have different ways of connection Please refer to the Installation manual of the Dome cameras when connecting the Keyboard 12V A B A...

Page 9: ...ctly So one controller can control the 31pcs PTZ speed dome directly most 2 In the system it can connect the 4pcs controller most each controller ID will different Matrix Dome1 Dome2 Figure 2 4 2 Cont...

Page 10: ...C adaptor 2 Connect the AC adaptor to NKB 3 2 START STOP controller Turn the switch to as Figure 2 1 to START the controller And turn to to STOP the controller Attention NKB will AUTO checking the BAU...

Page 11: ...the system we install the Onekey Ghost As for the Onekey Ghost pls follow the instruction to operate it First start the system and select the Onekey Ghost in the operation system list as Figure 3 3 2...

Page 12: ...Manual Manual operate GHOST 6 MS DOS Command DOS instruction operate 7 Restart Computer PRESS Chinese it will change to the Chinese language 3 3 1 One key back up Pls select the B on the Onekey Ghost...

Page 13: ...in E disk Pls do not delete the document All the DATA are in this fold otherwise it can not run the Onekey restore function as Figure 3 3 1 3 3 3 2 Onekey Restore Select the R OneKey Restore or direct...

Page 14: ...t will advise you the position about it as Figure 3 3 2 2 Select the BACK UP and press ENTER to the interface for confirm as Figure 3 3 2 3 And then select the OK to enter the GHOST screen or select t...

Page 15: ...erate on it and 15s can set by yourself later the light will close if you did not do any operate on it Figure 3 4 1 3 5 Control the PTZ speed Dome by Navigation key Navigation key has two functions on...

Page 16: ...e focuse Iris Press OPEN manual iris will enlarge and make more light into the camera Too much light will make the image too bright and expose Press CLOSE manual iris will close and make less light in...

Page 17: ...all the matrix main menu SHIFT SET Call the main menu the menu will display on the object monitor About the matrix function set up pls refer to the matrix s user manual 3 10 2 Confirm the setting ENTE...

Page 18: ...t up the NKB parameter 4 1 1 Setup keyboard ID Enter the main menu TFT will display as Figure 4 1 1 1 Figure 4 1 1 1 Press 1 to select the KEYBOARD SETUP it will show as Figure 4 1 1 2 Figure 4 1 1 2...

Page 19: ...lect the Baud Rate setting as Figure 4 1 2 1 Figure 4 1 2 1 2400bps 4800bps 9600bps 19200bps is available You can select the Baud rate you need and press the ENTER to save If your operation is success...

Page 20: ...o select the function you need and set it Here is the function you can set Preset Scan Pattern Tour Figure 4 2 1 1 Press 1 enter the dome Preset function setting as Figure 4 2 1 2 Figure 4 2 1 2 Item...

Page 21: ...2 2 Scan Enter the menu as Figure 4 1 1 1 Press 2 enter the dome setting menu as the Figure 4 2 1 1 Press 2 again to enter the dome scan setting as Figure 4 2 2 1 Figure 4 2 2 1 Dome scan setting inc...

Page 22: ...position and press the 1 to start record the pattern information The screen will display Start as the Figure 4 2 3 2 Press 0 to finish the pattern record and the screen will show Success and back to...

Page 23: ...col setting as Figure 4 3 1 4 3 1 Pelco Matrix model Press 1 enter the PELCO Matrix model as the Figure 4 3 1 1 And then press the ENTER to select the Protocol and back to previous menu Figure 4 3 1 1...

Page 24: ...de 2 Buzzer 3 key time s 4 LCD Backlight 5 USB Mode 6 Brightness 7 Contrast 8 Saturation 9 Language 10 Init System Press PREV to back PAL NTSC ON OFF 000 255 000 100 Mouse Pckey none 000 255 000 255 0...

Page 25: ...cable connected to residential cable TV network to achieve network communication DSL DSL is a series of related technologies that through the regular telephone line home and small business to provide...

Page 26: ...e it can reach as follow based on the different Baud rate Baud rate Max distance 2400bps 1800M 4800bps 1200M 9600bps 800M 19200bps 600M If user selects thinner cables or installs the dome in an enviro...

Page 27: ...nce performance arise when the cables are long in the connection The reliability of control signals are decreased with the phenomena that the dome dose not responds to or just responds at intervals to...

Page 28: ...ess NEAR near focus CLOSE High Speed dome camera Press CLOSE reduce iris OPEN High Speed dome camera Press OPEN increase iris SET N PRESET High Speed dome camera Adjust the image to object position pr...

Page 29: ...he sixteen domes of connection matrix forwards NEXT Matrix Press NEXT skip to the previous dome hold on 2sec on NEXT to continuously skip the sixteen domes of connection matrix back wards Stop Matrix...

Page 30: ...y standards between hard drive manufacturers and computer operating system Hard disk manufacturers used in hard disk capacity is 1000 binary that is 1G 1 000 MB 1MB 1 000 KB 1KB 1 000 byte However the...