background image

4

5

Engli

sh

Română

Important safety warnings

3

Please read carefully the following instructions before installing the unit. 

Do not operate this unit before reading through all safety information 

and operating instructions carefully!

Preparation

•   This battery bank is connected to an UPS. There will be voltage at the 

output terminals if the UPS is turned on even if the input AC Mains is 

not available.

•   Make sure that the AC Utility outlet is correctly grounded.

•   Do not try to repair the unit yourself, contact your local supplier or 

your warranty will be void.

Installation and connection warnings

•   Use a certified input power cable with the correct plugs and sockets.
•   To eliminate any overheating of the battery bank, keep all ventilation 

openings free from obstruction and do not place any foreign objects 

on top of the battery bank. Keep the battery bank 20 cm away from 

the wall. 

•   Make sure the battery bank is installed within the proper 

environment as specified: 0-40°C and 30-90% non-condensing 

humidity.

Storage and maintanance

•   The warranty for this battery bank will be void if water or other liquid 

is spilt or poured directly onto the battery bank. Similarly, warranty is 

void if any damage to the battery bank occurs due to foreign objects 

which are deliberately or accidentally inserted into the battery bank 

enclosure.

•   The battery will discharge naturally if the system is unused for a 

period of time. It should be recharged every 2-3 months if unused. 

If this is not done, then the warranty will be void. During normal 

operation, the batteries will be automatically charged.

•   Servicing of batteries should be performed or supervised by trained 

personnel only. When replacing batteries, replace with the same 

quantity, type & capacity. 

•   The unit contains no user-serviceable parts. If the battery service 

life has been exceeded, the batteries must be replaced. In this case, 

please contact your dealer.

Cautions regarding battery installation

•  

Do not install the battery bank under direct sunlight. Your 
warranty will be void if the batteries fail due to overheating. 

• 

This battery bank is designed for indoor use only. 

•  

This battery bank is not designed for use in dusty, corrosive 
and salty environment.

Other battery cautions

• 

Do not dispose of batteries in an open fire, they may explode. 

•  

Do not open or otherwise damage the batteries. The 
electrolyte from the batteries is toxic and harmful to the 
skin and eyes. Risk of electric shock! The battery circuit is 
not isolated from AC, hazardous voltage may exist between 
battery terminals and ground. Test before touching with 
bare hands.

•  

A battery can present a risk of electrical shock and high 
short circuit current.

Summary of Contents for Aster 1K

Page 1: ...Aster Series EBM User Manual Manual de utilizare UPBPCA0312FX CG01B UPBPCA0712FX CG01B Before using this product carefully read all product documentation and retain it for future reference 131 0 ...

Page 2: ...with an UPS The battery pack will provide or extend the backup time of your UPS Aster EBM CA0312F CA0712F Front view Aster EBM CA0312F CA0712F Back view NOTE Before installation please inspect the unit Be sure that nothing inside the package is damaged Keep the original package in a safe place for future use 1 2 3 1 On board Replaceable Fuse Cover Replaceable fuse is accessible from the rear panel...

Page 3: ...s due to foreign objects which are deliberately or accidentally inserted into the battery bank enclosure The battery will discharge naturally if the system is unused for a period of time It should be recharged every 2 3 months if unused If this is not done then the warranty will be void During normal operation the batteries will be automatically charged Servicing of batteries should be performed o...

Page 4: ...battery module on a flat stable surface with the front of the unit facing toward you Secure the battery module to your rack with four M5X12L screws at the front of the rack Located in position 2 position 5 4 2 Tower installation 1 Attach the base stands Tighten the screws M4X8L 8pcs of the base stands rackmount ears onto the bottom of the battery module 2 Attach dust covers Insert dust cover into ...

Page 5: ...nnect charging source prior to connecting or disconnecting battery terminals Do not plug or unplug the battery connector if UPS works in DC discharging mode IMPORTANT NOTE Please be aware that UPS models Aster 1K Aster 2K and Aster 3K support only ONE Battery module Step 1 Unscrew and remove the top cover from the battery module Step 2 Unscrew and unplug steel straps from the battery module Step 3...

Page 6: ... connect the cables as shown in the image below the following drawing indicates the fasten positions for the correct batteries connection D After connecting the cables rotate the batteries as shown below and close the lid of the tray the illustration shows only the battery positions not the cables E Place the trays back into the cabinet and connect the battery cables with the cabinet s cables as s...

Page 7: ...s rotate the batteries as shown below and close the lid of the tray the illustration shows only the battery positions not the cables C Place 6 batteries in the right tray and connect the cables as shown in the image below the following drawing indicates the fasten positions for the correct batteries connection D After connecting the cables rotate the batteries as shown below and close the lid of t...

Page 8: ... 5 Reasemble the steel straps and the top cover The cabinet is now ready to be connected to the UPS Connecting battery pack module 6 Follow the image below in order to connect the battery pack with Aster 1K Aster 2K and Aster 3K UPS with included cable IMPORTANT NOTE Please be aware that UPS models Aster 1K Aster 2K and Aster 3K support only ONE Battery module ...

Page 9: ...tru că ați ales produsele noastre Vă rugăm citiți cu atenție manualul de utilizare înainte de a pune în funcțiune acest produs Concentrându ne pe calitate la preţuri competitive construim produse pentru consumatori în ideea unei interacţiuni cât mai plăcute cu lumea digitală Cabinetul de baterii este un produs care funcționează doar împreună cu un UPS Acesta asigură sau suplimentează rezerva de en...

Page 10: ...inalele acestuia va exista curent electric chiar dacă intrarea UPS ului nu este conectată la rețea Verificați ca toate prizele să fie corect împământate Nu încercați să reparați dumneavoastră acest produs pentru orice problemă contactați centrul de service în caz contrar veți pierde garanția Avertizări privind conectarea și instalarea Vă rugăm să folosiți numai cabluri de alimentare și prize testa...

Page 11: ...u aruncați bateriile în foc fiindcă pot exploda Nu desfaceți ori distrugeți bateriile Electrolitul din acestea este toxic coroziv și vă poate afecta pielea și ochii Atenție risc de șoc electric Chiar și după ce aparatul este deconectat de la rețeaua electrică componentele din interiorul sistemului sunt încă conectate la baterie și pot fi încărcate electric și periculoase Înainte de a atinge cu mâi...

Page 12: ...a UPS sau de la alte echipamente înainte de a continua În cazul lucrului cu baterii vă rugăm Scoateți toate ceasurile inelele sau alte obiecte metalice de pe mâini Să folosiți doar instrumente cu mânere izolate electric Să utilizați mănuși și încălțăminte de protecție Să nu așezați obiecte de metal pe suprafața bateriilor fiindcă acestea pot produce un scurtcircuit Să deconectați sursele de încărc...

Page 13: ...entul stâng și conectați cablurile conform imaginii de mai jos poziția bateriilor indicată în imagine este pentru a facilita conexiunea cablurilor B După ce ați conectat cablurile rotiți bateriile conform imaginii de mai jos și închideți capacul compartimentului stâng poziția bateriilor indicată în imagine este cea finală C Plasați 3 baterii în compartimentul drept și conectați cablurile conform i...

Page 14: ...ile bateriilor la cele ale cabinetului conform imaginii de mai jos Pentru cabinetul de 72 Vdc UPBPCA0712FX CG01B A Plasați 6 baterii în compartimentul stâng și conectați cablurile conform imaginii de mai jos poziția bateriilor indicată în imagine este pentru a facilita conexiunea cablurilor B După ce ați conectat cablurile rotiți bateriile conform imaginii de mai jos și închideți capacul compartim...

Page 15: ...ți conectat cablurile rotiți bateriile conform imaginii de mai jos și închideți capacul compartimentului stâng poziția bateriilor indicată în imagine este cea finală E Plasați ambele compartimente înapoi în cabinet și conectați cablurile bateriilor la cele ale cabinetului conform imaginii de mai jos Step 5 Reasamblați benzile metalice din interior și capacul Cabinetul este pregătit pentru a fi con...

Page 16: ... a echipamentelor electrice și electronice Asigurându vă că acest produs este dezafectat în mod corect veţi ajuta la prevenirea posibilelor consecințe negative asupra mediului și a sănătații umane care ar fi putut surveni daca produsul ar fi fost dezafectat în mod necorespunzător Reciclarea materialelor vă ajută la conservarea resurselor naturale Folosind cablurile incluse conectați cabinetul de b...

Page 17: ...32 33 Memo Memo ...

Page 18: ... Feb 15 2020 Timişoara Stamp Date and location Signature and name EC conformity marking Tommy Lee EN 62040 2 2006 AC 2006 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 62040 1 2008 A1 2013 Feb 15 2020 Timişoara Declarație UE de conformitate Noi în calitate de producător importator declarăm că următoarele produse sunt conforme cu DAI TECH SRL 28 Popa Șapcă 300057 Timișoara Romania Testate în standardele a...

Page 19: ......

Reviews: