IMPORTANT
Installer and Users please note:
These instructions should be read carefully and left
with the user of the product for future reference.
Installation
Fix the Micro-4 with the hanging bracket provided, or
stand on a flat surface by rotating the hanging bracket
around the product, and using it as a foot, allowing it to be
tilted to any angle. If suspended, then a safety chain must
also be employed to conform to Health & Safety
Regulations.
The Micro-4 must be installed by a competent
electrician in accordance with the current IEE wiring
regulations.
Connect the Micro-4 to the mains supply using the built-
in mains lead.
• Brown = Live (phase)
• Blue = Neutral.
• Green/yellow = Earth.
• The Micro-4 must be earthed.
If connecting via a mains plug, fit a 3 Amp fuse in the
plug. If installing permanently, connect to a fuse or circuit
breaker of no more than 5 Amp rating. The Micro-4 should
not be connected to the output of a dimmer.
This symbol means that the Micro-4 should be
mounted more than 0.3 metres from any object
that it is illuminating.