Mode
Description
Values
Special Effects Settings
15
mm
“16” flashing
“mm” = value
Use LDR
. If you disable the LDR, the tubes will always work
at maximum brightness. If you enable it, the display
brightness will vary with the ambient lighting.
“1” = enable
“0” = disable
default: 1
16
mm
“17” flashing
“mm” = value
Blank Mode.
You can set the tubes, the LEDs or both the
tubes and the LEDs to be blanked when in blanking mode.
“0” = tubes
“1” = LEDs
“2” = tubes and
LEDs
default: 2
17
mm
“18” flashing
“mm” = value
Fade Speed Slower
. Each short press will make the fade
speed between digits slower.
Default: 50
Max: 200
Min: 20
18
mm
“19” flashing
“mm” = value
Fade Speed Faster
. Each short press will make the fade
speed between digits faster.
Default: 50
Max: 200
Min: 20
19
mm
“20” flashing
“mm” = value
Scroll-back Speed Slower.
Each short press will make the
“scroll-back” speed slower.
Default: 4
Max: 40
Min: 1
20
mm
“21” flashing
“mm” = value
Scroll-back Speed Faster.
Each short press will make the
“scroll-back” speed faster.
Default: 4
Max: 40
Min: 1
21
mm
“22” flashing
“mm” = value
Slots Mode.
You can have the date shown automatically
once per minute for about 5 seconds.
“1” = enable
“0” = disable
default: 1
22
mm
“22” flashing
“mm” = value
Separator LED Pattern.
Sets the flashing pattern for the
separator LEDs.
“0” = “Railroad”
“1” = “Slow blink”
“2” = “Fast blink”
“3” = “Double
blink”
23
mm
“23” flashing
“mm” = value
PIR Timeout Longer.
If you have a PIR or microwave
motion sensor installed, this setting determines how long
the clock will wait before turning the display off when there
is no motion detected. The value is in seconds.
Default: 300
Max: 3600
Min: 60
24
mm
“24” flashing
“mm” = value
PIR Timeout Shorter.
If you have a PIR or microwave
motion sensor installed, this setting determines how long
the clock will wait before turning the display off when there
is no motion detected. The value is in seconds.
Default: 300
Max: 3600
Min: 60
Back Light Settings