9 Initial Start-Up
NivuLink Compact - Document revision 02 / 06.08.2020
page 49
9.3.1 IP-Addresses NivuLink Compact and Host PC
NivuLink Compact:
Per default the ETHERNET interface (Port X1 und Port X2) of the controllers is set to the ad-
dress below:
Ethernet Interface
Default Setting
X1/X2
192.168.1.111
Tab. 9-2 Pre-set IP address of Ethernet interfaces
Host PC:
The default IP address of the controller is 192.168.1.111, the host PC must be within the
same subnet. Therefore, in the network mask 255.255.255.0 the first three digits of the host
PC must be the same as with the controller while the last digits must be different. This results
in the following address space for the host PC:
IP Address Controller
Subnet Address Space for the Host PC
192.168.1
.111
192.168.1
.00 …
192.168.1
.254
except
192.168.1
.111
Tab. 9-3 Network mask 255.255.255.0: IP addressing of host PC