background image

 

 
 
 
 

 

 

 

LoRa Data Logger 

IOT400-DL101

 

 

User Manual 

Summary of Contents for IOT400-DL101

Page 1: ...LoRa Data Logger IOT400 DL101 User Manual...

Page 2: ...CE RED Requirements 9 1 6 Hardware Installation 10 1 6 1 Mount the Unit 10 1 6 2 Connecting I O Devices 10 1 6 3 Connecting Console Port for PC Configuration Tool 13 1 6 4 Connect to external DC Powe...

Page 3: ...LoRa and LoRaWAN are optimized for low bandwidth IoT traffic over wide area to transmit data at low data rates It allows massive deployment of wireless IoT with carrier level security Main Features Si...

Page 4: ...1pcs 2 LoRa Antenna 1pcs 3 Terminal Block 1pcs 4 499 Ohm Resistor 1pcs 5 Power Adapter 1pcs 1 2 2 Optional Accessories Optional parts these parts are sold separately Items Description Contents Quanti...

Page 5: ...ation Left View Right View Reset Button RESET button provides user a quick and easy way to resort the default setting Press the RESET button continuously for 6 seconds and then release it The device w...

Page 6: ...ant Gateway and Network Server Configuration Tool Requirements Computer with the following Windows 7 or Windows 10 An installed Ethernet adapter A USB 2 0 or later for device configuration 1 5 2 WARNI...

Page 7: ...ment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution...

Page 8: ...e surface temperature for the metallic enclosure can be very high Especially after operating for a long time installed at a closed cabinet without air conditioning support or in a high ambient tempera...

Page 9: ...osure Statements The antenna of the product under normal use condition is at least 20 cm away from the body of user 4 Unit Mounting Notice The product is suitable for mounting at heights 2m approx 6 f...

Page 10: ...he field device s to the I O ports with the right pin assignments as shown below DO DI UART TX UART RX GND 1 2 3 4 5 6 7 8 9 10 DO DI AI GND PWR Mode Specification Analog Input 0 10V analog Voltage wi...

Page 11: ...LoRa Data Logger 11 Example of Connection Diagram DI Example of Connection Diagram DO...

Page 12: ...ice and properly connect and configure the IOT400 so that it can get the correct readings from the connected device The AI port supports either 0 10V voltage mode or 4 20mA current mode analog signal...

Page 13: ...ave to further configure software settings from a PC configuration tool The LPWA Data Logger provides one serial console port for device configuration You have to connect USB to Serial console cable I...

Page 14: ...Make sure the electrodes have been plugged into the right pins according to their assignments There is a DC12V 1A power adapter2 in the package for you to easily connect DC power adapter to this termi...

Page 15: ...ther device configuration When you execute the Configuration Tool you will see the login dialog Click the drop down menu next to the Serial Port Choose the COM port that is bound to the Data Logger s...

Page 16: ...LoRa Data Logger 16 Now you already logged in to the Data Logger console and you can proceed with the required software configuration steps one by one Refer to the following Chapter for the details...

Page 17: ...cated in the right hand side If the device status doesn t appear or you want to get the updated status click Status Refresh button located at the lower right corner to refresh the status immediately Y...

Page 18: ...ou can configure the channel activation settings and MAC Layer settings Channel Configuration There are Channel Group 1 and 2 It will show the supported Sub Band depend on the area of the LoRa specifi...

Page 19: ...pecify whether the TX Confirm ACK response from network server is applied or not for each data uplink transmission By default Confirm is selected Un Confirm No ACK response is required The LoRa Node w...

Page 20: ...mpler because you skip the join procedure DeviceEUI This is a unique and read only ID 64 bit for the LoRa node It is hardcoded by the device manufacture AppEUI This is an application ID 64 bit for the...

Page 21: ...ink transmission tx the node will listen for a response from gateway network server Class C C is for C ontinuous Same as A but Class C devices will listen continuously for responses from the gateway n...

Page 22: ...device type while it is powered by external battery The device won t get into sleep mode if it is configured as Class C device and it will continuously drain away the battery power even it is idle an...

Page 23: ...can specify a simple data conversion formula with the base fromat Physical Value Read Value Op 1 X Op 2 Y where Read Value the input value ex 7 5V or 12 4mA for a certain AI signal Op 1 and Op 2 both...

Page 24: ...appear for you to double confirm the settings of Analog Input type that the H W configuration and S W configuration are consistent After you confirmed the settings are correct click Yes button to sto...

Page 25: ...the condition part min hold time and the action part Condition part condition 1 AND OR condition 2 min Hold Time Above Condition remains TRUE for at least Thold condition hold time Action part make DO...

Page 26: ...the event happens condition TRUE for the pase Thold duration the specified action will be take accordingly Enable Check Enable to activate the event rule Finally click Save button to store the config...

Page 27: ...nd wait a while for the device to reboot Configuration Backup Restore In addition to the factory default settings you can also customize a special configuration setting as a customized default value W...

Page 28: ...ect the console cable while upgrading new firmware it is very likely to damage the device Once the Firmware Upgrade completed the device will be reboot with the new firmware immediately System Time Sy...

Page 29: ...29 2 6 CLI Console Log The system console log will show at this configuration page It can help to monitor the system operation and event When some issue happens capture this console log and consult wi...

Page 30: ...th of Command Total Length Data Data accompanied data bytes for the issued command Checksum Checksum byte for the complete command stream Command Total Length Data Direction The MSB of the Command cod...

Page 31: ...LoRa Data Logger 31 ret buf i return ret...

Page 32: ...t on the payload size This command may not be used for some Modbus device configuration that has many registers to read For example the packet 0115010000010100000901030300FA03C8DB64000093 is composed...

Page 33: ...entifier for each input port Only those enabled input ports will appear in the payload DI 1 0x10 DI 2 0x11 AI 1 0x30 AI 2 0x31 AI 3 0x32 Modbus 1 0x50 Modbus 2 0x51 Modbus 3 0x52 Data i Length the dat...

Page 34: ...port Only those enabled input ports will appear in the payload DI 1 0x10 DI 2 0x11 AI 1 0x30 AI 2 0x31 AI 3 0x32 Modbus 1 0x50 Modbus 2 0x51 Modbus 3 0x52 Data i Length the data length of the correspo...

Page 35: ...server is asking for the LoRa node to get the status data of all input ports Note 1 There is maximum limit on the payload size This command may not be used for some Modbus device configuration that ha...

Page 36: ...Total length Checksum 1 byte 1 byte 1 byte Command 0x82 Purpose A network server is asking for the LoRa node to get the status data of all enabled input ports For example the packet 820280 is composed...

Page 37: ...rresponding output port Data Value the data of the corresponding output port For a Modbus type port the data format is composed of Slave ID Function call Start Address Data Length Data 1 byte 1 byte 2...

Page 38: ...0x70 Total length Checksum 1 byte 1 byte 1 byte Command 0x70 Purpose A LoRa node is alerting to the network server with low battery power warning For example the packet 700272 is composed of Command...