Technical Instructions for
Correlation Sensors
Page 22
Correlation Sensors – Rev. 07 as of 20.04.2016
®
WARNING
Seal unused connection sockets
Unused connection sockets on the Type EBM Electronic Box shall be sealed
watertight by using the screw cover fastened on each socket prior to installa-
tion. Otherwise the protection grade of the entire unit is no longer guaranteed.
Damages resulting due to not using the covers are not covered by the manu-
facturer’s liability.
Covers being damaged or lost due to the use of force can be ordered from
NIVUS at extra costs.
Keep threads of plugs and sockets carefully free of dirt, sand or similar and
clean the threads with a soft and lint-free cloth prior to connection if required.
If placed in flood shafts or channels the transmitter must be secured in order
to prevent it from being washed away unintentionally (use suspension gear,
plastic or steel rope, chain or similar).
1. Ground plate
2. Sensors for level measurement using air-ultrasonic
3. Sensor body
4. Cable gland
5. Sensor cable
6. Plug with spigot nut
7. Fastening clamp for installation on ceiling
Fig. 3-6
Overview air-ultrasonic sensor, type DSM