Chapter 5: Monitor, Diagnostic, Maintenance
Monitor, Diagnostic, Maintenance
NGSME16T2H User Manual | 289
(right-most table).
Rx
Other
Requests
dot1xAuthBackendOtherRequestsToSupplicant
802.1X-based
:
Counts the number of times that the
switch sends an EAP Request packet
following the first to the supplicant.
Indicates that the backend server
chose an EAP-method.
MAC-based
:
Not applicable.
Rx
Auth.
Successes
dot1xAuthBackendAuthSuccesses
802.1X- and MAC-based
:
Counts the number of times that the
switch receives a success indication.
Indicates that the supplicant/client has
successfully authenticated to the
backend server.
Rx
Auth.
Failures
dot1xAuthBackendAuthFails
802.1X- and MAC-based
:
Counts the number of times that the
switch receives a failure message.
This indicates that the
supplicant/client has not authenticated
to the backend server.
Tx
Responses
dot1xAuthBackendResponses
802.1X-based:
Counts the number of times that the
switch attempts to send a supplicant's
first response packet to the backend
server. Indicates the switch attempted
communication with the backend
server. Possible retransmissions are
not counted.
MAC-based:
Counts all the backend server packets
sent from the switch towards the
backend server for a given port
(left-most table) or client (right-most