Page 2: ...treatment 2 Power On Device Turn on device by pressing the power button for roughly 1 second Identify the reject tone While holding the device in front of you and making sure the device tip has NO direct contact with the skin press and release the treatment button You will hear a set of quick low pitched beeps that indicate a rejection pulse The rejection tone indicates that the device tip did not...

Page 3: ...eye Power down the device by holding down the power button until the NIRA logo and power level lights turn off Continue with daily skincare regimen For Best Results repeat this process daily for 90 days or more To enhance your results you may treat twice daily Press and release the power button to adjust the power level Set your NIRA Laser to level 1 Place the device tip on the skin as shown to th...

Page 4: ...r skin activating the skin to produce collagen like it did decades ago to give you the healthy beautiful and youthful looking skin that you deserve The NIRA Skincare Laser provides lasting results to reverse the signs of aging in as little as 8 to 12 weeks using advanced dermatologist tested technology Before using your device for the first time it is important to read the instructions and safety ...

Page 5: ...D USE WHEN TO USE ACHIEVING BEST RESULTS WHAT TO EXPECT 10 PRE TREATMENT INSTRUCTIONS 11 TREATMENT GUIDELINES 12 CHARGING INSTRUCTIONS 14 CLINICAL STUDY RESULTS 15 CLEANING STORAGE SERVICE AND MAINTENANCE 16 LABELS AND SPECIFICATIONS 17 TRAVEL AND DISPOSAL 18 TROUBLESHOOTING 19 EMC INFORMATION 20 CONTACT INFORMATION 24 ...

Page 6: ...uble Insulation Electrical Appli ance Non ionizing Radiation Use only with NIRA Supply Unit Read Operator s Manual Laser Radiation Warning WARNING Do not use this appliance near bathtubs showers basins or other vessels containing water Consult Instruction For Use IP22 Protection against finger sized ob jects Protected against dripping water The device is not submersible Type BF Applied Part Temper...

Page 7: ... on pages 7 and 8 prior to using the NIRA Skincare Laser WHEN TO USE INDICATIONS The NIRA Skincare Laser is an over the counter device intended to treat periorbital wrinkles wrinkles around the eyes WHEN NOT TO USE CONTRAINDICATIONS Do not use on skin that is cut burned or infected Only use on skin that is intact Do not use if under 12 years of age or with reduced physical sensory or mental capabi...

Page 8: ...ents 12 and over Do not point or place the treatment tip over your eye or eyelid serious or permanent eye damage may result Do not place or drop your device or charger near or into water or liquid Do not use the device while bathing Doing so could result in serious injury Always keep the cord away from heated or wet surfaces to prevent damage to the device Ensure the skin and treatment tip are dry...

Page 9: ...IRA Skincare Laser Only use the charger and USB C cord supplied to recharge the device Using a different charger or USB C cord could cause device malfunc tion or serious injury Do not drop the device on hard surfaces as the device could be damaged The NIRA Skincare Laser complies with standards regarding electromagnetic fields EMF If handled properly and according to the instructions in this bookl...

Page 10: ...ce improvements within the first few weeks but notice the most dramatic results after 2 3 months of daily use The first treatment session is usually the longest so it s best to start when you have more time Within a few uses most users complete a full treatment around the eyes 40 pulses per eye in 2 3 minutes Immediately after treatment you may feel a warming sensation similar to how a mild sunbur...

Page 11: ...full contact with the skin If you hear this tone during treatment you need to reposition the device tip making sure there is full skin contact Step Five Set the treatment power level to 1 by pressing and releasing the power button quickly until only one light displays in the power level setting area Illustration of power levels low to high is shown to the right Test this power level by placing the...

Page 12: ...e previous treatment spot See illustration for overlapping pattern then press and release the treatment button again Repeat this process for 40 pulses on one eye following the 2 3 row pattern shown in the illustra tion Once completed you will hear a set of three fast paced jingle like tones that indicate the treatment for that eye is complete For best results use the device daily according to the ...

Page 13: ... You will hear a power down set of beeps and the lights will turn off The device will automatically power down after 2 minutes with no activity It is recommended to clean the exterior of the Laser after each use with a damp cloth Step Five Continue with your daily skincare routine The use of a moisturizer and sunscreen with SPF of 30 or greater on the treatment area is recommended For Best Results...

Page 14: ...equates to several weeks of daily usage between charges This time will vary with settings and will lessen as the battery ages Your NIRA Skincare Laser will not work when it is plugged into the battery charger Unplug your NIRA Skincare Laser before treatment Charger State Battery Indicators Condition Charger disconnected Normal operation Battery over half charge Normal operation Battery less than h...

Page 15: ...5 months 63 of users saw 1 full wrinkle scale unit improvement within 6 months 22 of users saw 2 full wrinkle scale unit improvements within 6 months 69 of users saw 1 full wrinkle scale unit improvement within 7 months 36 of users saw 2 full wrinkle scale unit improvements within 7 months 10 of users saw 3 full wrinkle scale unit improvements within 7 months 81 of users maintained wrinkle improve...

Page 16: ...lens and remove any debris If debris has fallen into the laser output window and it will not come out using the cotton swab gently shake the device to let the debris fall out Disinfect all surfaces with 70 alcohol solution between each use ENVIRONMENT CONDITIONS The NIRA Skincare Laser should be used in a comfortable environment Temperature 15 C to 35 C 59 F to 95 F Relative Humidity 30 75 Atmosph...

Page 17: ...CC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular inst...

Page 18: ...n integral part of our sustainability policy we ask you to observe the following Do not throw away the device with the normal household waste at the end of its life but hand it in at an official collection point for recycling This device contains a built in lithium ion rechargeable battery that cannot be removed This rechargeable battery contains substances that may pollute the environment To ensu...

Page 19: ...l Usage light lowest level blinking Replenish Usage 3 Call NIRA Customer Service 5 All Front lights off can t treat Turn off NIRA and Turn back on If not resolved call Customer Service 7 Charge NIRA by plugging into electrical outlet 8 Call NIRA Customer Service 9 Call NIRA Customer Service 10 Release Treatment button Call NIRA Customer Service 11 Call NIRA Customer Service 12 Release Power button...

Page 20: ...er Warnings The NIRA Skincare Laser should not be used adjacent to or stacked with other equipment treatments Electromagnetic Emissions Declaration The NIRA Skincare Laser is intended for use in the electromagnetic environment specified below The customer or the user of the NIRA Skincare Laser should assure that it is used in such an environment RF emissions CISPR 11 Group 1 The NIRA Skincare Lase...

Page 21: ...hould be that of a typical home commercial or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode Complies Mains power quality should be that of a typical home commercial or hospital environment Voltage dips short interrupts and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT For 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in ...

Page 22: ... an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects a...

Page 23: ...ansmitter W Separation distance according to frequency of the transmitter M 150 kHz to 80 MHz d 1 17 150 kHz to 80 MHz d 1 17 150 kHz to 80 MHz d 2 33 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 1 17 1 17 2 33 10 3 70 3 70 7 37 100 11 70 11 70 23 30 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using equation appli...

Page 24: ...Dermal Photonics 100 Corporate Pl Suite 303 Peabody MA 01960 Customer Care 781 451 1700 info niraskin com www niraskin com ...