7. Make sure the compressed air supply couplings are secure.
If the screw threads of the couplings do not match perfectly, or if they
are not screwed in far enough, the hoses and couplers etc. could come off
while the tool is in use, possibly causing accident or injury.
*Refer to section one (p.4) for details of part names.
*A warning label is stuck to the chamber of this tool. If the label is badly
damaged or if it peels off, contact your supplier or one of our offices to
obtain a replacement (a replacement fee will be charged).
Caution!
1. Before servicing this tool, replacing any of its parts, or otherwise
assembling or disassembling it, be sure to disconnect all compressed air
couplings and to make sure it is not supplied with compressed air.
If you start to work on this tool while it is supplied with compressed air,
parts or oil could fly out or the tool could start moving unexpectedly,
causing accident or injury.
2. The fill screws must be fully tightened before you use this tool.
If any of the fill screws are loose or missing, oil can spurt out, causing
accident or injury.
3. Do not operate this tool while the nose housing off.
Your fingers could be trapped and injured by the exposed parts.
4. Do not grip or turn the mandrel with your fingers etc. while the tool is
connected to its compressed air supply, and do not operate in condition
with the mandrel pointed to anyone.
The mandrel could start moving and may cause trouble or injure your
fingers.
5. Hold the work material with jigs not to rotate mandrel together.
Work material may causes a trouble or injury for turning round with
mandrel.
6. Only use parts that are provided or recommended by Nippon POP
Rivets and Fasteners. Attach the appropriate parts to this tool for the
POP Nuts you are using.
Other than reducing performance, using the wrong attachments could
cause malfunctions leading to accident or injury.
7. Do not alter the tool without permission from the manufacturer.
Resulting malfunctions could lead to accident or injury.