4. Installation
4. Installation
An external ground connection is provided at the right side of inverter.
Prepare OT terminals: M4. Use proper tooling to crimp the lug to the terminal.
Figure4.19
Connect the external grounding conductor
.19.
.18.
To protect the inverter's AC grid connection conductors, Solis recommends installing
breakers that will protect against overcurrent. The following table defines OCPD ratings
for the Solis mini single phase inverters.
4.3.4 Max. over current protection device (OCPD)
Note:
Connection for Split phase grid.
When connect to 208/220/240V split phase, please connect L1 to “L” terminal,
L2 to “N” terminal. Also connect earth to ground terminal.
4.3.3 External ground connection
d) Connect the AC grid terminal connector to the inverter. Small click will confirm
connection.
Figure 4.18 Connect the AC Connector to the Inverter
The inverter can be monitored via Wi-Fi or GPRS. All Solis communication devices are
optional (Figure 4.20). For connection instructions, please refer to the Solis Monitoring
Device installation manuals.
Inverter
Solis-mini-700-4G
Rated
voltage(V)
Current for protection
device (A)
10
Solis-mini-3600-4G
Solis-mini-1000-4G-LV
Solis-mini-3000-4G
Solis-mini-2500-4G
Solis-mini-2000-4G
Solis-mini-1500-4G
Solis-mini-1000-4G
20
20
15
15
10
10
Table 4.3 Rating of grid OCPD
4.3.5 Inverter monitoring connection
Figure4.20 Communication function
Internet
GPRS monitoring
Wi-Fi monitoring
Smart phone monitoring
PC monitoring
Web server
Router
Wi-Fi monitoring
Wi-Fi box
220/230
220/230
220/230
220/230
220/230
220/230
220/230
Rated output
current (A)
3.2/3.0
4.5/4.3
6.8/6.5
9.1/8.7
13.6/13
16
11.4/10.9
101/120/127
15
8.3