Troubleshooting
POSEIDON 5 NEW-NA5_en_Ver.1.0_20/12
46
E
By-pass valve failures.
1
2
3
4
5
Symptom:
Machine doesn’t start when
activating the spray gun.
Cause:
Defective reed contact (3) or piston
(2) is stuck.
Remedy:
Replace defective parts.
Symptom:
Irregular working pressure.
Cause:
Injector nozzle (4) is worn.
Remedy:
Replace injector nozzle.
Symptom:
Low working pressure
Cause:
By-pass valve kit worn and leaks
water.
Remedy:
Replace By-pass valve kit.
Symptom:
Suction inlet for detergent leaks
water.
Cause:
Non return valve (5) defective.
Remedy:
Replace non return valve.
Pic. E2: By-pass valve..