GB
D
F
NL
I
N
S
DK
SF
E
P
GR
TR
SLO
HR
SK
CZ
PL
H
RO
BG
RUS
EST
LV
LT
J
CN
ROK
T
MAL
10
1)
OEL = Occupational exposure limit
ATTIX 995-0H/M SD XC Type 22
The vacuum cleaner ATTIX 995-0H/M SD XC
is suitable to pick up
dry, nonflammable dust, non flammable
•
liquids, sawdust and hazardous dusts with
OEL values
1)
, carcinogenic dusts, dusts
containing germs
flammable, dry dust in Zone 22
•
The vacuum cleaners
ATTIX 995-0H/M SD XC is also approved for
asbestos abatement (TRGS 519).
Use the cleaner only if it is certain that no ac-
tive sources of ignition can be sucked in.
Conductive extraction equipment, e.g. extrac-
tion hoods on machines and conductive parts
of machining equipment (e.g. equipment
in protective class II) that are not earthed
through the cleaner, must be earthed in some
other way to prevent electrostatic charges.
When picking up flammable dust in Zone 22,
the dirt tank must be emptied as required, but
always after use.
The vacuum cleaner must be used only, if all
filters, as well as the filter for the motor cool-
ing air, are attached and without damage.
The cleaner is not suitable for extraction on
machining equipment in operation that could
produce sources of ignition.
When dust removers are used, the rate at
which air is exchanged in the room must be
adequate if the exhaust air from the vacuum
cleaner is blown into the room (please ob-
serve regulations valid in your country).
The vacuum cleaner is suitable for commer-
cial use, such as e.g. in
Hotels, Schools, Hospitals, Factories,
•
Shops, Offices, Hire shops
Any other use is considered as improper use.
The manufacturer accepts no liability for any
damage resulting from such use. The risk for
such use is borne solely by the user.
Proper use also includes proper operation,
servicing and repairs as specified by the
manufacturer. See operating instructions.
Operation
Depending on how hazardous the dust is, the
cleaner must be fitted with appropriate filters:
Type of dust
Filter bag/waste bag
Non-hazardous
•
dust
Non-carcino-
•
genic dust with
OEL values
>
0.1 mg/m³ (ob-
serve any ad-
ditional national
regulations)
Waste bag
(5 pcs.)
Order No.
302001480
All dusts with
•
OEL values
Wood dust
•
Explosive dust,
•
dust explosion
class St1, St2,
St3 in Zone 22
Safety filter
bag (5 pcs.)
Order No.
302003473
All dusts with
•
OEL values
Wood dust
•
Explosive dust,
•
dust explosion
class St1, St2,
St3 in Zone 22
Filter element
“H”
Order No.
302001137
Before picking up dust with occupational
exposure limit values:
Check that all the filters are present and
1.
properly fitted.
Do not use the cleaner with damaged or
2.
missing antistatic clamp. Risk of explo-
sion due to static discharge in explosive
atmospheres.
The hose diameter and the setting for the
3.
suction hose diameter must be the same.
When the motor is running, hold the
4.
suction hose shut. For safety reasons, an
acoustic warning sounds if the air speed in
the suction hose drops to below 20 m/s.
Transport
Before transporting the dirt tank, close all
1.
the locks.
Make sure that both plugs are inserted in
2.
fittings.
Do not tilt the cleaner if there is liquid in
3.
the dirt tank.
Do use a crane hook to lift the cleaner.
4.