Nilfisk-ALTO ATTIX 360-2M Operating Instructions Manual Download Page 17

15

english

ATTIX 360-2M

ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC

1) 

Option depending on model

 

   

EC declaration of conformity

Alto Deutschland GmbH
Guido-Oberdorfer-Straße 2-8
D-89287 Bellenberg

Product:

Model:

Description:

The design of the appliance 
corresponds to the following 
pertinent regulations:

Applied harmonized standards:

Applied national standards and 
technical specifications:

Dipl.-Ing. Wolfgang Nieuwkamp
Tests and approvals

Vacuum cleaner for wet and dry operation

ATTIX 360-2M/550-2M/560-2MXC
ATTIX 751-2M/761-2MXC

110/230-240 V~, 50/60 Hz, 1200 W, Dust class M

EC Machine Directive 98/37/EC
EC Low Voltage Directive 73/23/EC
EC EMC Directive 89/336/EC

EN 12100-1, EN 12100-2
EN 60335-1
EN 60335-2-69
EN 55014-1, EN 55014-2, EN 61000-3-2

DIN EN 60335-1
DIN EN 60335-2-69

Bellenberg, 22.10.2004

Suction hose diameter 

mm

Minimum air flow volume

l/min

Associated negative pressure 

between suction hose/tool

Pa

27

690

16300

32

970

15700

36

1220

14200

50

2360

7800

9.5 Accessories

Description

Order No.

360-2M

550-2M

560-2MXC

Filter bag (5 pcs.)

302000449

302000527

302001138

Waste bag (5 pcs.)

302000804

302000728

Filter element 

302000461

302000726

Cloth insert filter

302000606

302000525

751-2M

761-2MXC

Filter bag (5 pcs.)

302001484

Waste bag (5 pcs.)

302001480

Filter element 

302000461

302000726

Cloth insert filter

302000525

360-2M / 550-2M / 560-2MXC 

751-2M / 761-2MXC

Protective filter bag 
(10 pcs.)

30082

Filter screen

15475

Nilfisk-Alto-Foam-
Stop (6 x 1 l)

8469

9.6 

EC declaration of conformity

9.4 Technical 

data

ATTIX

360-2M

550-2M

560-2MXC

751-2M

761-2MXC

EU

GB

230/240V

EU

GB

230/240V

GB

110V

EU

EU

EU

Voltage

V

230

230/240

230

230/240

110

230

230

230

Mains frequency

Hz

50/60

Fuse

A

16

13

16

13

16

16

16

16

Power consumption

W

1200

Connected load for 
appliance socket

W

2400

1800

2400

1800

560

2400

2400

2400

Total connected load

W

3600

3000

3600

3000

1760

3600

3600

3600

Volume flow (air)

l/min

3600

Negative pressure

Pa

23000

Measurement area sound 
pressure level at a distance of 
1 m, EN 60704-1

dB(A)

62

60

Operating noise

dB(A)

59

57

Power cord: Length

m

7,5

10.0

7,5

10.0

7,5

7,5

7,5

7,5

Power cord: Length

H05RR- F3G1,5

H07BQ-

F3G1,5

H05RR- 

F3G1,5

H05RR- F3G1,5

Protection class

I

Type of protection 
(splash water protec-
ted)

 IP X4 

Radio interference 
level

EN 55014-1 

Tank volume

l

27

45

70

Width

mm

380

476

580

Depth

mm

390

506

605

Height

mm

570

655

970

Weight

kg

10

14

25

27

Summary of Contents for ATTIX 360-2M

Page 1: ...sull uso 61 75 norsk Driftsinstruks 76 90 svensk Bruksanvisning 91 105 dansk Driftsvejledning 106 120 suomi K ytt ohje 121 135 slovens i Navodilo za uporabo 136 150 hrvatski Uputstvo za rad 151 165 sl...

Page 2: ...TTIX 360 2M ATTIX 550 2M ATTIX 560 2MXC ATTIX 751 2M ATTIX 761 2MXC auto 1 4 3 5 6 7 3 11 9 8 10 ATTIX 3 14 auto 9 8 2 3 5 6 7 ATTIX 5 1 4 auto 14 ATTIX 7 2 3 4 1 5 5 6 8 10 12 12 13 10 9 14 auto auto...

Page 3: ...2 3 Suction power control 6 4 3 Check volume flow monitor 6 4 4 Acoustic warning 7 4 5 Cleaning the filter element ATTIX 360 2M 7 4 6 Cleaning the filter element ATTIX 560 2MXC 761 2MXC 7 5 1 Techniqu...

Page 4: ...e country of use ob serve recognized regulations for safety and proper use Do not use any unsafe work techniques Purpose and intended use The vacuum cleaners described in this operating manual are sui...

Page 5: ...level indicator hose ATTIX 560 2MXC 761 2MXC to limit the water level and check that they are not damaged See section 5 for information on handling liquids and hazard ous dust Electrical components C...

Page 6: ...there is no danger for maintenance staff or other persons In the maintenance area use filtered compulsory ven tilation wear protective clothing clean the maintenance are so that no harmful substanc e...

Page 7: ...on of the vacuum cleaner The mains plug should not be in serted into a socket 3 To pick up dust with maxi mum room concentration values Insert the filter bag into the dirt tank according to the instru...

Page 8: ...e socket on the control panel To comply with regulations only ap proved dust producing tools should be connected The maximum power consumption of the connected power tool is stat ed in section 9 4 Tec...

Page 9: ...ng stream of air removes attached dust from the slats of the filter elements To ensure that suction perform ance is always at its best the filter element is automatically cleaned during operation We r...

Page 10: ...hould be washed and dried or replaced by a dry element be fore dry substances are picked up Always use a filter bag waste bag that is suitable for the type of dust see table ATTIX 360 2M Type of dust...

Page 11: ...ount of foam use foam killer Nilfisk Alto Foam Stop see section 9 5 Accesso ries for order number 6 After finishing work 6 1 Switching the vacuum cleaner off and storage 1 After picking up hazardous d...

Page 12: ...aining clamps 1 and remove the intermediate ring 2 from the tank 3 Carefully remove the waste bag connection from the inlet fitting 4 Close the waste bag using the cable binder 3 5 Dispose of the dirt...

Page 13: ...r Before reinserting the suction hose 5 Clean the inlet fitting and hose collar Only after picking up harmless dust without a filter bag 7 2 4 Emptying the dirt tank ATTIX 7 1 Remove the upper section...

Page 14: ...e filter holder and turn it clockwise to secure it firmly 10 Dispose of the used filter ele ment in accordance with legal regulations Never use the vacuum cleaner without a filter During the following...

Page 15: ...onnect mains fuse Overload protection switch has tripped Switch off the vacuum cleaner and allow it to cool for approx 5 minutes If the cleaner can not be started again contact the Nilfisk Alto servic...

Page 16: ...sult of technical advances 9 3 Tests and approvals The vacuum cleaners have been tested as specified in IEC EN 60335 2 69 including appendix AA All the requirements were fulfilled for equipment in dus...

Page 17: ...e bag 5 pcs 302000804 302000728 Filter element 302000461 302000726 Cloth insert filter 302000606 302000525 751 2M 761 2MXC Filter bag 5 pcs 302001484 Waste bag 5 pcs 302001480 Filter element 302000461...

Page 18: ...OWERBANK 7AY ILWILLY NDUSTRIAL STATE 5 0ENRITH UMBRIA 1 4EL AX MAIL SALES NILFISK ALTO CO UK 7EB WWW NILFISK ALTO CO UK 93 4 3 ALAYSIA 3DN HD 3 ALAN 0 4AMAN 0ERINDUSTRIAN 0 32 AMANSARA UALA UMPUR ALA...