5  Applications and techniques

5.1 Techniques

If used correctly, additional ac-
cessories, suction nozzles and 
suction hoses can enhance the 
cleaning action and reduce the 
cleaning effort.

Effective cleaning is achieved if 
you follow just a few guidelines 
in combination with your own 
practical experience in special 
fields.
Here are some basic tips.

5.1.1  Picking up dry 

substances

The suction hose diameter must 
suit the position of the switch in 
order to pick up dry, nonflam-
mable dust with maximum room 
concentration values.
There must always be a safety 
filter bag in the tank before dry 
substances with maximum room 
concentration values are picked 
up. See section 9.5 “Accesso-
ries” for ordering number.

To pick up harmless dust we 
recommend the use of a waste 
bag. See section 9.5 “Accesso-
ries” for ordering number. Dis-

posal of the picked up material 
is then simple and hygienic.

After picking up liquids, the filter 
element is wet. A damp filter el-
ement clogs more quickly when 
dry substances are picked up. 
For this reason the filter element 
should be washed and dried or 
replaced by a dry element be-
fore dry substances are picked 
up.

Always use a filter bag/waste 
bag that is suitable for the type 
of dust (see table):

ATTIX 360-2M

Type of dust

Filter bag/waste bag

Handling/waste disposal

• Nonhazardous 

dust

Waste bag
No. 302000804

1.  Thorough cleaning - see section 4.5.
2.  Waste disposal - see section 7.2.1
Waste disposal - see section 7.2.2

• 

Dust with MAC 
values 

 0.1 mg/m³ 

• wood 

dust

Filter bag
No. 302000449

Waste disposal - see section 7.2.2

ATTIX 550-2M

Type of dust

Filter bag/waste bag

Handling/waste disposal

• Nonhazardous 

dust

Waste bag
ATTIX 550-2M: No. 302000728
ATTIX 751-2M: No. 302001480

Waste disposal - see section 7.2.1

• 

Dust with MAC 
values 

 0.1 mg/m³ 

• wood 

dust

Filter bag
ATTIX 550-2M: No. 302000527
ATTIX 751-2M: No. 302001484

Waste disposal - see section 7.2.2

ATTIX 560-2MXC

Type of dust

Filter bag/waste bag

Handling/waste disposal

• N

onhazardous dust

• 

Dust with MAC 
values 

≥ 

0.1 mg/m³ 

• 

Observe any ad-
ditional national 
regulations

Waste bag
ATTIX 560-2MXC: No. 302000728
ATTIX 761-2MXC: No. 302001480

Waste disposal:
1. Remove hose with tool sleeve from 
tool
2. Thorough cleaning - see section 4.6
3. Waste disposal - see section 7.2.1

• 

Dust with MAC 
values 

 0.1 mg/m³ 

• wood 

dust

Filter bag
ATTIX 560-2MXC: No. 302001138
ATTIX 761-2MXC: No. 302001484

Waste disposal - see section 7.2.2

Do not pick up flammable 
substances.

Summary of Contents for ATTIX 360-2M

Page 1: ...sull uso 61 75 norsk Driftsinstruks 76 90 svensk Bruksanvisning 91 105 dansk Driftsvejledning 106 120 suomi K ytt ohje 121 135 slovens i Navodilo za uporabo 136 150 hrvatski Uputstvo za rad 151 165 sl...

Page 2: ...TTIX 360 2M ATTIX 550 2M ATTIX 560 2MXC ATTIX 751 2M ATTIX 761 2MXC auto 1 4 3 5 6 7 3 11 9 8 10 ATTIX 3 14 auto 9 8 2 3 5 6 7 ATTIX 5 1 4 auto 14 ATTIX 7 2 3 4 1 5 5 6 8 10 12 12 13 10 9 14 auto auto...

Page 3: ...2 3 Suction power control 6 4 3 Check volume flow monitor 6 4 4 Acoustic warning 7 4 5 Cleaning the filter element ATTIX 360 2M 7 4 6 Cleaning the filter element ATTIX 560 2MXC 761 2MXC 7 5 1 Techniqu...

Page 4: ...e country of use ob serve recognized regulations for safety and proper use Do not use any unsafe work techniques Purpose and intended use The vacuum cleaners described in this operating manual are sui...

Page 5: ...level indicator hose ATTIX 560 2MXC 761 2MXC to limit the water level and check that they are not damaged See section 5 for information on handling liquids and hazard ous dust Electrical components C...

Page 6: ...there is no danger for maintenance staff or other persons In the maintenance area use filtered compulsory ven tilation wear protective clothing clean the maintenance are so that no harmful substanc e...

Page 7: ...on of the vacuum cleaner The mains plug should not be in serted into a socket 3 To pick up dust with maxi mum room concentration values Insert the filter bag into the dirt tank according to the instru...

Page 8: ...e socket on the control panel To comply with regulations only ap proved dust producing tools should be connected The maximum power consumption of the connected power tool is stat ed in section 9 4 Tec...

Page 9: ...ng stream of air removes attached dust from the slats of the filter elements To ensure that suction perform ance is always at its best the filter element is automatically cleaned during operation We r...

Page 10: ...hould be washed and dried or replaced by a dry element be fore dry substances are picked up Always use a filter bag waste bag that is suitable for the type of dust see table ATTIX 360 2M Type of dust...

Page 11: ...ount of foam use foam killer Nilfisk Alto Foam Stop see section 9 5 Accesso ries for order number 6 After finishing work 6 1 Switching the vacuum cleaner off and storage 1 After picking up hazardous d...

Page 12: ...aining clamps 1 and remove the intermediate ring 2 from the tank 3 Carefully remove the waste bag connection from the inlet fitting 4 Close the waste bag using the cable binder 3 5 Dispose of the dirt...

Page 13: ...r Before reinserting the suction hose 5 Clean the inlet fitting and hose collar Only after picking up harmless dust without a filter bag 7 2 4 Emptying the dirt tank ATTIX 7 1 Remove the upper section...

Page 14: ...e filter holder and turn it clockwise to secure it firmly 10 Dispose of the used filter ele ment in accordance with legal regulations Never use the vacuum cleaner without a filter During the following...

Page 15: ...onnect mains fuse Overload protection switch has tripped Switch off the vacuum cleaner and allow it to cool for approx 5 minutes If the cleaner can not be started again contact the Nilfisk Alto servic...