107
Service Manual – SC401, SCRUBTEC 344
24 - Electrical System (Battery)
Battery Charge State Display
Low Voltage Cut Out
The Main machine controller (EB1) shuts off electrical loads to protect the batteries from damage caused by
over discharging
The voltage threshold where loads are turned off depends on the battery type See table below
Significant Levels for Machine Operation
Level
Battery status LEDs
Voltage in
WET setting
Voltage in
GEL setting
CONSEQUENCE
B+ (V)
B+ (V)
A
>23,5
>23,5
-
B
>23,0
>23,2
-
C
>22,5
>22,9
-
D
>22,0
>22,6
-
E
>21,4
>22,2
-
F
>20,4
>21,6
Little remaining run time, no block
G
<20.4
<21.6
Brush and Vacuum system OFF
19.0
Drive system OFF