Service Manual – SC401, SCRUBTEC 344
05 - Control System - Cord
User Interface Controller (EB2) and Operator’s Presence Sensors (S1, S2)
User Interface Controller (EB2)
1 Make sure that the scrubber is disconnected from the power supply
2 Unscrew the 2 screws (A) and open the user interface controller cover (B)
3 Disconnect the following connections:
◦
(C) and (D), left and right Operator’s presence sensors connection
◦
(E) User interface controller power supply connection (J201)
4 Carefully remove the User interface controller (F) detaching it from the cover (B)
5 Clean the cover area from the glue remained of the User interface controller removed
Figure 17:
A
A
B
D
F
C
E
6 Assemble the components in the reverse order of disassembly
Note: