Solution System
81
Service Manual – SC2000
Troubleshooting (Continues)
Trouble
Possible Causes
Remedy
The EcoFlex™ system detergent is not
reaching the brush, or is not arriving in
sufficient quantity
The detergent flow percentage is too low
Check/change the percentage as
shown in the User Manual
The hydraulic circuit upstream of the detergent pump is
not triggered
Check if the hose is filled and, if
necessary, perform one or more
draining cycles
The pump (M1) is broken or there is an open in the
electrical connection
Replace the pump/repair the
electrical connection
There is foreign material/debris in the detergent tank
clogging the output hole
Clean the tank
There is debris in the detergent hoses clogging the
detergent flow
Clean the hoses
The detergent flow adjustment button
is not
working correctly
Check that the LED turns on,
otherwise replace the dashboard
instrument electronic board (EB4)
Function electronic board (EB1) faulty
Replace
Display electronic board (EB2) faulty
Replace
Dashboard instrument electronic board (EB4) faulty
Replace
The EcoFlex™ system detergent
is reaching the brush even with the
machine off
The pump (M1) is broken
Replace
The one-way valve is broken
Replace
Water is entering the EcoFlex™ system
tank
The one-way valve is broken
Replace
The EcoFlex™ system will not activate
and the LED does not come on
Dashboard instrument electronic board (EB4) faulty
Replace
The function electronic board (EB1) has not been set for
operation with the EcoFlex™ system
If present, remove the jumper
(J6) on the rear of the function
electronic board
Figure 7