18
9.6. Trouble Shooting and Remedy
Fault
Cause
Remedy
No pressure /
too low pressure
Insufficient or No water supply
Open water supply valve
(See 5.1 – Closing valve)
Rinsing nozzle is not installed
Place rinsing nozzle
Insufficient or
No foam creating
No supply of diluted products
Consult directions for use of
dosing unit
Product is not suitable
Choose suitable product
Incorrect nozzle
Place foam nozzle
Non-return valve is blocked
Clean or replace non-return
valve
Injector /mixing chamber
blocked
Clean nozzle
No spray
sanitising
No supply of dilute products
Consult directions for use of
dosing unit
Non-return valve is blocked
Clean or replace non-return
valve
Injector /mixing chamber is
blocked
Clean Injector /mixing chamber
In case of errors/troubles not mentioned above, please contact your local
service technician for further assistance.