INSTALL THE BRUSHES (CYLINDRICAL SYSTEM)
1 Verify which brush or pad is appropriate for the floor surface to be cleaned.
2 Make sure the Scrub Deck
(8)
is in the RAISED position. Make sure the Key Switch
(27)
is off.
CAUTION !
Turn the key switch off (O) and remove the key, before changing the brushes, and before opening any access panels.
1 Make sure the Scrub Deck is in the RAISED position. Make sure the Key Switch
(27)
is in the OFF position (O).
2
See Figure 2-5.
Remove both side blade assemblies.
NOTE:
The blade assemblies are held in place by Side Blade Assembly Removal
Knobs
(15)
. Loosen these knobs and slide the Side Blade Assemblies
(BA)
slightly forward and then off the Scrub Deck.
3 Loosen the Knobs
(BB)
on top of the Idler Assemblies
(BC)
and remove the assembly.
4 Slide the Brush
(BD)
into the deck housing, lift slightly, push and turn until it seats. Re-install the Idler Assemblies
(BC)
and Side Blade
Assemblies
(BA)
.
FIGURE 2-5
BA
BD
BB
15
BC