DRIVE SYSTEM
SERVICE MANUAL
ENGLISH
BA 451 / BA 451D / BA 531 / BA 531D / BA 551 / BA 551D / BA 551CD / BA 611D
CA 451 / CA 531 / CA 551
909 6756 000(
5)2010-03
93
TROUBLESHOOTING (Continues)
DRIVE SYSTEM ELECTRONIC BOARD DIAGNOSTIC TABLE
No. of flashes
(*)
Meaning
Action
1
Drive system/brush enabling microswitch closed when
starting the machine
Check the microswitch adjustment
2
Faulty speed potentiometer
Check both speed potentiometers
3
Faulty speed potentiometer
Check both speed potentiometers
4
Speed potentiometer off neutral when starting the machine
Check the speed potentiometer adjustment
5
Thermal protection
Check the drive system motor electrical input
6
Faulty drive system electronic board
Replace the drive system electronic board
7
Overcurrent output
Check the drive system motor electrical input; if the electrical
input is normal, replace the drive system electronic board
8
Missing power connection
Check the drive system fuse and the drive system electronic
board wiring harness; if the fuse and the wiring harness are
normal, replace the drive system electronic board
9
Low battery voltage
Charge the batteries
10
High battery voltage
Check the batteries
11
Overload output
Check the drive system motor electrical input
12
(Not applicable)
--
13
Ignition key wrong sequence
Check for false contacts in the ignition key – function
electronic board – drive system electronic board circuit
(orange cables)
14
Software error
Replace the drive system electronic board
(*) Flashing of led (A) of the drive system electronic board (B).
A
B
S301565