ELECTRICAL SYSTEM
ENGLISH
SERVICE MANUAL
98
909 6756 000(
5)2010-03
BA 451 / BA 451D / BA 531 / BA 531D / BA 551 / BA 551D / BA 551CD / BA 611D
CA 451 / CA 531 / CA 551
BATTERY TYPE SETTING (WET OR GEL) (For BA 451D, BA 531D, BA 551D, BA 551CD, BA 611D)
Set the electronic board of the machine and of the battery charger (if equipped) according to the type of batteries installed (WET or
GEL) as shown below:
Machine setting
Turn the ignition key (80) to “I” position and pay attention to the following in the very first seconds of machine operation:
1.
If the green warning led (81a) is flashing, the machine is set to GEL.
•
If the red warning led (81c) is flashing, the machine is set to WET.
•
If the setting is to be changed, perform the following procedure.
2.
Turn off the machine by turning the ignition key (80) to “0”.
3.
Press and hold the switches (71) and (73) at the same time, then turn the ignition key (80) to “I”.
4.
Release the switches (71) and (73) at least 8 seconds after starting the machine.
5.
Within three seconds, press the switch (73) again for a few seconds and check that the warning led for the required setting is
6.
flashing (as shown in step 1).
Battery charger setting (if equipped)
Remove the battery charger data inspection window screws (A).
7.
Remove the window (B).
8.
Turn the battery charger selector (C) to WET position for lead batteries, or to GEL position for gel batteries.
9.
Install the window (B) and tighten the screws (A).
10.
C
A
A
B
S301567