SERVICE MANUAL
ENGLISH
BR 601 / BR 651 / BR 751 / BR 751 C
909 6424 000(3)2007-12
69
DRIVE SYSTEM
FORWARD/REVERSE GEAR PEDAL POTENTIOMETER CHECK AND ADJUSTMENT
Remove the forward/reverse gear pedal (see the procedure in the relevant paragraph).
At the workbench, remove the screws (A), then remove the protection (B).
Apply a tester on the connector centre contact (C) and on the side contact (D), then check that the resistance is 2,500 ± 500
Ω
(Ohm) when the pedal is released. If necessary, reset the resistance correct value by loosening the screw (F) and operating on
the potentiometer screw (E). Then tighten the screw (F).
Install the protection (B) and tighten the screws (A).
Install the forward/reverse gear pedal (see the procedure in the relevant paragraph).
S301350
1.
2.
3.
4.
5.