70
- FORM NO. 56043098 - Convertamatic
™
24, 26, 28, 32 / BA 625, 725, 825
ELECTRICAL SYSTEM
MAIN CONTROL PROGRAMMING OPTIONS (CONTINUED)
LCD Style Selection:
FACTORY DEFAULT: RECTANGULAR SHAPE WITH THREE BARS
LCD graphic style can be programmed to different style. There are two different styles and to change LCD graphic style, perform the following steps:
1
Turn the main power key switch to the off position.
2
Press and hold the scrub on and vacuum switch.
3
While holding both switches, turn the main power key switch to the on position.
4
Continue to hold the both switches until the vacuum indicator and scrub on indicator turn yellow.
5
Release both switches. The display will now show current graphic style. The scrub off switch will turn red.
6
Pressing scrub on switch will now select between two different graphic styles and the display will be updated with new graphic style.
7
Press scrub off switch to save the setting. Turn the main power key switch to the off position.
8
The new setting will be saved and will remain in effect until it is changed again.
Monitor Mode:
The CONVERTAMATIC is equipped with a monitor mode where the 3 machine settings shown below can be quickly checked for the machine’s speci
fi
c set up. In
order to monitor current settings, perform following steps:
1
Turn the main power key switch to the off position.
2
Press and hold the recycle switch.
3
While holding the recycle switch turn the main key switch to the on position.
4
Continue to hold the recycle switch until the recycle indicator turns yellow.
5
Release the recycle switch.
6
The display will display current
deck setting, low voltage cutout
setting
and
error checking
setting
.
7
To exit this mode, turn the main power key switch to the off position.
Chemical User Ratio Selection:
FACTORY DEFAULT: 8
There are 9 different settings for chemical ratio. Without magnet, user chemical ratio can be achieved. To change user chemical ratio, perform following steps:
1
Turn the main power key switch to the off position.
2
Press and hold the chemical switch.
3
While holding the chemical switch turn the main key switch to the on position.
4
Continue to hold the chemical switch until the chemical indicator turns yellow.
5
Release the chemical switch.
6
The display will display chemical bottle with current user ratio. Chemical indicator will turn green.
7
Pressing chemical switch will now select chemical setting (32, 50, 64, 100, 128, 150, 200, 256, 300).
8
Press scrub off switch to save new setting. The display will show key switch icon.
9
Turn the main power key switch to the off position.
10 The new setting will be saved and will remain in effect until it is changed again.
NOTE:
Program to the desired ratio needed when not using a chemical container
(cartridge) that uses the magnetic slider.
Summary of Contents for BA 625
Page 2: ......
Page 7: ...FORM NO 56043098 Convertamatic 24 26 28 32 BA 625 725 825 5 SPECIFICATIONS revised 5 07 ...
Page 25: ...FORM NO 56043098 Convertamatic 24 26 28 32 BA 625 725 825 23 FIGURE 2 SCRUB SYSTEM ...
Page 27: ...FORM NO 56043098 Convertamatic 24 26 28 32 BA 625 725 825 25 NOTES ...
Page 55: ...FORM NO 56043098 Convertamatic 24 26 28 32 BA 625 725 825 53 FIGURE 4 ...
Page 57: ...FORM NO 56043098 Convertamatic 24 26 28 32 BA 625 725 825 55 FIGURE 5 ELECTRICAL SYSTEM ...
Page 63: ...FORM NO 56043098 Convertamatic 24 26 28 32 BA 625 725 825 61 FIGURE 6 ELECTRICAL SYSTEM ...
Page 79: ...www nilfisk advance com 2008 ...