![Nilfisk-Advance Advolution 2710 Service Manual Download Page 52](http://html.mh-extra.com/html/nilfisk-advance/advolution-2710/advolution-2710_service-manual_1693193052.webp)
52
- FORM NO. 56043107 - Advolution
™
2710
/ UHR 70-1700
ELECTRICAL SYSTEM
ADVOLUTION PROGRAMMING MODES
Forward Motion Alarm Volume Level Adjustment Mode:
FACTORY DEFAULT: 0 (OFF)
The control system has the ability to activate a forward alarm signal to alert personnel of the approach of the machine. The volume of this alarm is
adjustable from 0 to 9. 0 is off and 9 is the maximum volume setting. To adjust the volume of this alarm perform the following steps: (Note: while in
this mode, activating the foot pedal in the forward direction will activate the alarm so that the appropriate sound level can be selected).
1 Press and hold the horn switch while turning the key switch on.
2 Continue holding the horn switch until the status display is scrolling the word “SELECT”.
3 Release the horn switch.
4 Press and release the horn switch four times. The status display should now be scrolling “HORN F.”
5 Press and release the pad switch to enter the forward motion alarm volume adjustment mode.
6 The status display will now show “.F.” to indicate the forward alarm mode as well as a number from 0 to 9.
7 To select the desired volume level, press and release the horn switch. This will scroll through the available settings.
8 To save the setting and exit this mode turn the key switch off.
Reverse Motion Alarm (Back-Up Alarm) Volume Level Adjustment Mode:
FACTORY DEFAULT: 2 (LOW VOLUME)
The control system has the ability to activate a reverse alarm signal to alert personnel of the approach of the machine. The volume of this alarm is
adjustable from 0 to 9. 0 is off and 9 is the maximum volume setting. To adjust the volume of this alarm perform the following steps: (Note: while in
this mode, activating the foot pedal in the reverse direction will activate the alarm so that the appropriate sound level can be selected).
1 Press and hold the horn switch while turning the key switch on.
2 Continue holding the horn switch until the status display is scrolling the word “SELECT”.
3 Release the horn switch.
4 Press and release the horn switch
fi
ve times. The status display should now be scrolling “HORN R.”
5 Press and release the pad switch to enter the reverse motion alarm volume adjustment mode.
6 The status display will now show “.r.” to indicate the reverse alarm mode as well as a number from 0 to 9.
7 To select the desired volume level, press and release the horn switch. This will scroll through the available settings.
8 To save the setting and exit this mode turn the key switch off.
Burnishing Speed Limit Enable/Disable Mode:
FACTORY DEFAULT: LO (REDUCED BURNISHING SPEED)
The control system has the ability to limit the burnishing speed to a level programmed into the Curtis speed control. This limit can be overridden to
allow burnishing at full speed. To enable or disable this speed limiting feature, perform the following steps:
1 Press and hold the horn switch while turning the key switch on.
2 Continue holding the horn switch until the status display is scrolling the word “SELECT”.
3 Release the horn switch.
4 Press and release the horn switch six times. The status display should now be scrolling “BURNISH SPEED”
5 Press and release the pad switch to enter the speed limit enable/disable mode.
6 The status display will now show “HI” or “LO” to indicate the selected burnishing speed limit. Selecting LO will limit the burnishing speed to
the programmed limit in the speed control. Selecting HI will allow full speed burnishing.
7 To select the desired speed limit, press and release the horn switch. This will alternate between the two settings.
8 To save the setting and exit this mode turn the key switch off.
Summary of Contents for Advolution 2710
Page 7: ...FORM NO 56043107 Advolution 2710 UHR 70 1700 7 TECHNICAL SPECIFICATIONS ...
Page 15: ...FORM NO 56043107 Advolution 2710 UHR 70 1700 15 FIGURE 1 ...
Page 27: ...FORM NO 56043107 Advolution 2710 UHR 70 1700 27 WHEEL DRIVE SYSTEM FIGURE 2 ...
Page 36: ...36 FORM NO 56043107 Advolution 2710 UHR 70 1700 FIGURE 10 FIGURE 11 ...
Page 44: ...44 FORM NO 56043107 Advolution 2710 UHR 70 1700 FIGURE 5 ...
Page 58: ......
Page 59: ......
Page 60: ...www nilfisk advance com 2006 ...