40 - Recovery System
91
Service Manual – SC250, Scrubtec 334, MA 30
Vacuum System Motor Amperage Test (continues)
3 Apply the amp clamp (C) to the electrical cable (D) of the vacuum system motor
4 Switch on the machine and operate it with one hand on the handlebar
5 Check that the vacuum system motor current draw is between 5 5 and 6 5 A at 36 V
6 If the current draw is higher, remove the vacuum system motor (see the procedure in the Vacuum
System Motor Disassembly/Assembly paragraph), and check the condition of all its components to detect
and correct the reason for the abnormal current draw:
If the above-mentioned procedures do not produce the correct readings for the vacuum system motor
current draw, the motor must be replaced
Figure 7
C
D