MAIN CONTROL PROGRAMMING OPTIONS (CONTINUED)
Light Scrub Setting Adjustment:
FACTORY DEFAULT: SCRUB PRESSURE = ONE BAR, SOLUTION= ONE BAR, DETERGENT= 0 (IF AVAILABLE).
The light scrub pressure, solution rate and detergent rate can be programmed depending on its application where high solution rate is needed with light scrub
pressure or low solution rate with heavy scrub pressure. To change all or any one setting, scrub, solution and detergent, perform the following steps:
1
Turn the main power switch to the off position.
2
Press and hold the scrub on and wand switch.
3
While holding both switches, turn the main power key switch to the on position.
4
Continue to hold both switches until wand switch indicator turns on and the light scrub on switch indicator blinks.
5
Release both switches. The display will now show a scrub icon (either disc or cylindrical) with the current scrub pressure setting. Scrub off indictor will turn on
and light scrub indicator will blink.
6
Pressing the scrub on switch will now select the new scrub pressure. Pressing scrub off switch will save the new setting and move to the solution rate setting.
7
The display will now show solution icon with gauge. Light scrub indicator will stop blinking and solution indicator will blink. Pressing solution switch will now
select solution rate. Pressing scrub off switch will save the new setting and move to detergent setting (if available).
8
On machines equipped with the optional detergent system the display will now show detergent bottle with current setting. Detergent indicator will blink. Pressing
detergent switch will now select new detergent setting. Pressing scrub off switch will save the new setting and display the key switch icon.
9
Turn the key switch to the off position, the new settings will remain in effect until it is changed again.
SCRUB PRESSURE & CURRENT LOAD (AMPS) SPECIFICATIONS (TABLE 2)
Scrub Mode
Scrub Pressure
Indicator
DECK TYPE
Disc BR 1100S
Cyl. BR 1100S
Disc BR 1300S
Cyl. BR 1300S
Light Scrub
1 bar(#1)
40 AMPS
35 AMPS
50 AMPS
35 AMPS
Heavy Scrub
2 bars(#2)
50 AMPS
45 AMPS
60 AMPS
45 AMPS
Extreme Scrub
3 bars(#3)
65 AMPS
55 AMPS
80 AMPS
55 AMPS
SOLUTION FLOW RATE (TABLE 3)
Standard
fl
ow rates
Over-ride
fl
ow rates
1 bar
2 bars
3 bars
4 bars
5 bars
BR 1100S Disk
.84 GPM
1.00 GPM
1.50 GPM
2.00 GPM
2.50 GPM
BR 1100S Cylindrical
.70 GPM
.84 GPM
1.00 GPM
1.50 GPM
2.50 GPM
BR 1300S Disk
1.00 GPM
1.50 GPM
2.00 GPM
2.25 GPM
2.50 GPM
BR 1300S Cylindrical
.84 GPM
1.00 GPM
1.50 GPM
2.00 GPM
2.50 GPM
DETERGENT SETTINGS (TABLE 4)
0
Normal detergent setting
-
10% less than normal detergent setting
+
10% more than normal detergent setting
Summary of Contents for 56413006
Page 7: ...FORM NO 56043122 BR 1100S 1300S 5 SPECIFICATIONS ...
Page 9: ...FORM NO 56043122 BR 1100S 1300S 7 FIGURE 1 ...
Page 10: ...8 FORM NO 56043122 BR 1100S 1300S THIS PAGE INTENTIONALLY BLANK ...
Page 36: ...34 FORM NO 56043122 BR 1100S 1300S 4 RECOVERY SYSTEM FIGURE 4 2 ...
Page 39: ...FORM NO 56043122 BR 1100S 1300S 37 SQUEEGEE SYSTEM 5 FIGURE 5 2 ...
Page 47: ...FORM NO 56043122 BR 1100S 1300S 45 WHEEL DRIVE SYSTEM 6 FIGURE 6 5 ...
Page 53: ...FORM NO 56043122 BR 1100S 1300S 51 REAR WHEEL SYSTEM 7 FIGURE 7 3 ...
Page 61: ...FORM NO 56043122 BR 1100S 1300S 59 ELECTRICAL SYSTEM 8 J Ø 4 K Fault Indicator 03 FIGURE 8 7 ...