Service Manual-AS1050R
04 Control System 21
Troubleshooting
Access to Panel Parameter Setting
1.
Power off the machine. Press “scrub pr” and “scrub pressure -” button at the same time and power
up the machine (Figure 1).
2.
LCD will display “Input password” in 4 seconds, then release the two buttons (Figure 2).
3.
Input the first digit of the password “661” by pressing “scrub pr” button, (Figure 3).
4.
Confirm the first digit by pressing “scrub pr” and “scrub pressure -” buttons at the same time. LCD
will display the input status of the second digit (Figure 4).
5.
Input the second digit by pressing “scrub pr” button and confirm it. Input the third digit and confirm it.
LCD will display “***” (Figure 5).
6.
Confirm the password by pressing “brush release” button. LCD will display system setting menu (Figure 6).
7.
Confirm selection by pressing “brush release” button. Then LCD will display the first parameter of “Panel
Setting” (Figure 7).