![Niles INTELLIPAD CI Installation Manual Download Page 14](http://html1.mh-extra.com/html/niles/intellipad-ci/intellipad-ci_installation-manual_1692534014.webp)
Connecting the Keypad Modules
1. Run and terminate the four-pair twisted cable with an RJ-45 connector.
Note:
The Keypad Modules require a one-to-one wiring configuration. To maintain consis-
tency throughout all IntelliPad Ci installations, we recommend the color-coding pattern
described in
Figure 12
. However, you may follow the color-coding pattern of your choice,
as long as it is used consistently throughout the system.
2. Connect the terminated cable to a Master Keypad Module. Position the Master Keypad
Module as the first Keypad Module to the left when installing more than one Keypad
Module.
3. If installing Accessory Keypad Modules, connect the first Accessory Keypad Module to the
Master Keypad Module using the cable included with the Accessory Keypad Module.
See
Figure 3
.
4. If you have more than one Accessory Keypad Module to install, connect the second
Accessory Keypad Module to the first.
5. If using an IR Sensor, connect it to the Master Keypad Module.(see Niles MultiZone Control
Systems Installation and Operation Guide for instructions)
6. If installing an IntelliPad Ci Silencer, it should always be placed furthest to the right in the
J-box or P-ring, because it only has one jack. (Keypad Modules have an IN and an OUT jack.)
13
Figure 12
I
N T E L L I
P
A D
®
C
I
K
E Y P A D
M
O D U L E S
1 = Green/White
2 = Green
3 = Orange/White
4 = Blue
5 = Blue/White
6 = Orange
7 = Brown/White
8 = Brown
DS00266CCN-0 IntelliPad Ci.qxp 2/2/06 3:30 PM Page 15