AUTOMATION CTS602

CTS602 Control

The CTS602 HMI touch panel is featuring a wide range of functions, 
e.g., menu-controlled operation, weekly programme settings, filter 
monitor with timer, fan speed adjustment, summer bypass (free 
cooling), supply-heating element control, error messages etc.

The CTS602 comes with factory settings, including a default setting 
which can be customised to operational requirements to achieve 
optimum operation and utilisation of the system. 

There is an option for selecting between 2 front page images for 
the main screen.

Operating instructions for the CTS 602 can be found in a separate 
user manual supplied with the unit.

External communication

The CTS602 control unit communicates by default with 
Modbus RTU RS485 communication. A CTS system using this 
form of communication can easily be connected to the unit.

Nilan units have an open Modbus communication, i.e. not only 
can the unit be monitored, but its operation can also be set in 
the same way as it can via the operating panel.

The protocol is by default set up for a Modbus RTU30 
address; however, values can be set between 1 and 247.

A Modbus converter allows you to connect one or more units 
to a computer to monitor and control the unit.

A Nilan gateway is fitted as standard on the Comfort 600, where the user can 
gain access to the unit via a Nilan User APP. The APP enables the user to access 
and monitor the current operation, also from the outside of the property.

The APP allows you to adjust the default settings of, for instance, room tempe-
rature, fan speed level and the humidity control system.

The APP shows when filter change is next due. This is an important function, 
and you are automatically notified when filters need changing or an alarm is 
triggered.

It also provides you with useful trend curves so you can follow the operation of 
the unit for the previous week with regards to, for instance, room temperature 
or humidity level.

Using a LAN connector, you connect the gateway to the Modbus of the unit and 
then to the user’s internet router via a LAN or a WiFi connection. This creates a 
secure cloud connection between the unit and the smartphone.

Nilan User APP

Summary of Contents for GO GREEN COMFORT 600

Page 1: ...COMFORT600 BY NILAN PRODUCTDATA Domestic Ventilation 800 m3 h Passive heat recovery Ventilation passive heat recovery...

Page 2: ...as been thoroughly tested with improvements being continually made during its manufacture for more than 15 years These have focused on low energy consumption easy user operation and maintenance The Co...

Page 3: ...han aluminium exchangers The efficient fans are powered by energy saving EC motors They provide a constant air volume with a four step adjustment The unit comes with a clear and user friendly HMI touc...

Page 4: ...s operation for system with SFP value 1000 J m3 ved 500 m3 h Technical specifications Trade mark Nilan Model Comfort 600 Type Two way ventilation unit not for residential Type of drive Variable speed...

Page 5: ...6 7 7 7 6 7 200 495 215 314 504 3 2 1 4 4 1 2 3 1200 630 950 495 315 636 446 200 495 225 504 314 5 7 7 6 200 495 215 314 504 3 2 1 4 200 495 225 504 314 630 5 950 495 225 636 446 6 7 7 4 1 2 3 630 95...

Page 6: ...90 G4 filters and no heating element SFPvaluescomprisetheunit stotalpowercomsumptionincl control Conversion factor Attention The SFP values are measured and stated as a total value for both fans Nilan...

Page 7: ...th falling air volume and falling back pressure Sound output level LpA at a given distance will depend on acoustic conditions in the place of installation Octave band Hz Surface dB A Supply air dB A E...

Page 8: ...the air exchange if the air humidity fluctuates This ensures that the unit always runs at its most efficient based on the actual air humidity level and not on a theoretical one This helps save energy...

Page 9: ...ting supply and the CTS 602 control The water heating element includes copper pipes and aluminium fins Capacities can be seen in the table below Water side Air side Temperature input output C Flow m3...

Page 10: ...t can via the operating panel The protocol is by default set up for a Modbus RTU30 address however values can be set between 1 and 247 A Modbus converter allows you to connect one or more units to a c...

Page 11: ...protection In order to protect a potential water after heating element against frost damage the unit will stop and display an alarm if the temperature in the water after heating element becomes too lo...

Page 12: ...nsate drain the water trap works well However during the summer months when there is no condensation of extract air the water trap will dry out and therefore cease to prevent false air intake A Nilan...

Page 13: ...to the primary heating supply Supplied with two way adjustment valve temperature sensor and frost thermostat Water heating element incl regulation The supply temperature can always be raised to the r...

Page 14: ...for an office it may be acceptable to decrease the operating level at night t Temperature efficiency Operation Ice building Ice building Defrost Defrost With pre heater Defrost function Outdoor temper...

Page 15: ...in 40 cm Transport and storage Comfort 600 comes in factory packaging that protects it during transport and storage Comfort 600 must be stored in a dry place in its original packaging until installati...

Page 16: ...are available to down load for planning purposes WWW NILAN DK Visit us at www nilan dk to find out more about our company and solutions download further information and find your nearest dealer Nilan...

Reviews: