A54
・
-
VBA12001-R.3668.A
7. Required equipment and conditions
※
AC adapter EH-5 and USB cable (mini B type) UC-E4 are used for all adjustments so they are not
specified in the list.
Item
Required device
Setting/Remarks
1
Sensitivity adjustment
・
5100K color viewer
J63070
(
ex-model viewer J63049 is also
available.)
・
Luminance meter BM-3000
J63068
・
Tool lens
(
to fix aperture
)
J61185
・
ND filter
(
ND8×1+ND4×2
)
Equivalent to luminance LV13
Aperture F8
52 mm,5-step light reduction; Use
the packaged product
2
Gr/Gb compensation
adjustment (R/B filter)
・
5100K color viewer
J63070
(
ex-model viewer J63049 is also
available.)
・
Luminance meter BM-3000
J63068
・
Tool lens
(
Fixed aperture
)
J61185
・
SP3 (R filter)
J63087
・
SP1 (B filter
)
J63085
Equivalent to luminance LV13
Aperture F5.6
3
Sensitivity ratio adjustment
・
5100K color viewer
J63070
(
ex-model viewer J63049 is also
available.)
・
Luminance meter BM-3000
J63068
・
Tool lens
(
to fix aperture
)
J61185
Equivalent to luminance LV13
Aperture F8; No filter
4
Gr/Gb compensation
inspection (No filter)
・
5100K color viewer
J63070
(
ex-model viewer J63049 is also
available.)
・
Luminance meter BM-3000
J63068
・
Tool lens
(
to fix aperture
)
J61185
Equivalent to luminance LV13
Aperture F5.6; No filter
5
CCD black point defect
compensation
・
5100K color viewer
J63070
(
ex-model viewer J63049 is also
available.)
・
Luminance meter BM-3000
J63068
・
Tool lens
(
to fix aperture
)
J61185
Equivalent to luminance LV13
Aperture F5.6
6
CCD white point defect
compensation
Bo
dy cap or lens cap
Environmental temperature
approx. 20 - 25
℃
7
Sensitivity, sensitivity ratio
reference value calculation
Same as "Sensitivity adjustment"
No filter when sensitivity ratio
reference value is calculated.
8
TFT angle of view adjustment None
Only for NTSC (unnecessary for
PAL)
9
Reading of RISC version
None
★
New established tool