- R4
・
-
VBA18001-R.3719.A
M
サービス
計画課
Jan.25.2008
Additional page
Items
Judgment standard
Remarks
Standby (idle) /
consumed current
Main SW / OFF:� 2���� μA or less
(Do NOT press any operational buttons.
)
Main SW / ON (Half-release timer:� OFF):� 25�� μA or less
Main SW / ON (Half-release timer:� ON):� 25��
m
A or less
Main SW / ON (Illumination:� ON):� 28�� mA or less
Main SW / ON (TFT ON):� 3���� mA or less
Main SW / ON (
Live view ON):
200 mA or less
Constant-voltage
power source
Battery tool
Ammeter
AF50/.4
EV2
Operation time /
consumption current
accumulated
Lens scan
AF50/.4D
Operation time: 850 ms or less
Consumption current accumulated: 450 mAsec or less
AF28-70/3.3-4.5D
Operation time: 00 ms or less
Consumption current accumulated: 550 mAsec or less
AF80-200/2.8D
Operation time: 200 ms or less
Consumption current accumulated: 700 mAsec or less
Preview Operation time: 90 ms or less
Consumption current accumulated: 20 mAsec
0 mAsec or less
Release without memory card
Operation time: 220 ms or less
Consumption current accumulated: 300 mAsec
Constant voltage
power source
Battery tool
Special tool
Oscilloscope
LV2
Rush current
Shooting operation: 8. A or less
Constant voltage
power source
Battery tool
Special tool
Oscilloscope
LV2
Clock accuracy
Difference par month: ±30 seconds (20
℃)
Wave clock
BC level
Level 5
5 lights up
Charge remaining: 8
~
00 %
Level 4
4 lights up
Charge remaining: 6
~
80 %
Level 3
3 lights up
Charge remaining: 4
~
60 %
Level 2
2 lights up
Charge remaining: 2
~
40 %
Level
light up
Charge remaining:
~
20 %
Level 0
light blinking
Charge remaining: 0%
Check the level in
the LCD control
panel on top of
camera or TFT
battery information
Communication-
capable battery tool
Bulb battery life
When special Li-ion is used:� 3 and a half hours or more
Clock
Remote wire
INC
Summary of Contents for D3 VBA18001
Page 134: ...INC ...