EN nv
Niko
sa Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: [email protected] — www.niko.eu
PM350-20085R17304
350-20085
10
• If you press and hold the push button
while the lighting is switched on
, the lighting switches off.
The mini detector is then blocked as long as activity is detected, and the preset switch-off delay + 2
hours have not yet elapsed. After that, the mini detector works again according to the selected settings,
and the lighting is switched on.
• If you press and hold the push button
while the lighting is switched off
, the lighting switches
on (depending on the level of daylight present). The lighting remains switched on as long as the mini
detector detects activity and the preset switch-off delay + 2 hours has not yet elapsed. After that, the
lighting is switched off, the mini detector works again according to the selected settings, and the lighting
is switched on.
The red status LED on the mini detector flashes (0.25 s on and 5 s off) to indicate that you have pressed
and held the push button. You can interrupt the ‘press and hold’ function at any time by pressing the push
button briefly. After doing so, the lighting is switched on or off, and the mini detector once again works
according to the selected settings.
Example 2: Garage
Operation of the presence detector:
• The lighting
automatically switches on
when the mini detector detects motion in the detection range
and the light level is below the preset lux value.
• The lighting is once again
automatically switched off
, after a preset time period (switch-off delay), if the
mini detector does not detect any more motion in the detection range or if the ambient light level exceeds
the preset lux value for a period of five minutes.
• You can manually
switch on the lighting using the push button
, depending on the level of daylight
present. If there is sufficient light in the room, the lighting will only be switched on by a long push on the
button.
6. MAINTENANCE
Dirt can influence the operation of the mini detector. For that reason, always keep the lens clean and dry. To
clean the lens, use a damp cloth and water with a small amount of detergent. Never apply any pressure to the
lens while cleaning. If the lens or another part of the mini detector is defective, please contact an authorized
installer.
7. TROUBLESHOOTING
Problem
Cause
Solution
The light is on for 5 s and
then off for 55 s.
The mini detector's pulse mode
was activated with the remote
control.
• Press
Lock/
unlock
Short
push
Learn actual lux
20
Lux
50
Lux
100
Lux
300
Lux
400
Lux
200
Lux
500
Lux
700
Lux
1000
Lux
No
Lux
Fact.
setting
Long
push
Test
On/Off
App.
Auto
App.
Active
Light
On/Off
Memory
in
Status
Time
30min
60min
15min
8
Hours
Pulse
2min
5min
10min
Memory
out
Clear
memory
three times to reset
the detector.
• Then press
Lock/
unlock
Short
push
Learn actual lux
20
Lux
50
Lux
100
Lux
300
Lux
400
Lux
200
Lux
500
Lux
700
Lux
1000
Lux
No
Lux
Fact.
setting
Long
push
Test
On/Off
App.
Auto
App.
Active
Light
On/Off
Memory
in
Status
Time
30min
60min
15min
8
Hours
Pulse
2min
5min
10min
Memory
out
Clear
memory
.
• Finish by pressing
Lock/
unlock
Short
push
Learn actual lux
20
Lux
50
Lux
100
Lux
300
Lux
400
Lux
200
Lux
500
Lux
700
Lux
1000
Lux
No
Lux
Fact.
setting
Long
push
Test
On/Off
App.
Auto
App.
Active
Light
On/Off
Memory
in
Status
Time
30min
60min
15min
8
Hours
Pulse
2min
5min
10min
Memory
out
Clear
memory
once.
Warning: the detector will now
be restored to its factory settings
(see section 3.1.). To change
these, follow the steps in section
4.1.
I am unable to set the mini
detector. The light is on for 5
s and whenever the sensor
detects activity, the red
indication LED flashes.
The mini detector is in test mode.
Exit the test mode in one of the
following ways:
• press
Lock/
unlock
Short
push
Learn actual lux
20
Lux
50
Lux
100
Lux
300
Lux
400
Lux
200
Lux
500
Lux
700
Lux
1000
Lux
No
Lux
Fact.
setting
Long
push
Test
On/Off
App.
Auto
App.
Active
Light
On/Off
Memory
in
Status
Time
30min
60min
15min
8
Hours
Pulse
2min
5min
10min
Memory
out
Clear
memory
on the IR remote
control
• press the connected push button
briefly
• press test
Lock/
unlock
Short
push
Learn actual lux
20
Lux
50
Lux
100
Lux
300
Lux
400
Lux
200
Lux
500
Lux
700
Lux
1000
Lux
No
Lux
Fact.
setting
Long
push
Test
On/Off
App.
Auto
App.
Active
Light
On/Off
Memory
in
Status
Time
30min
60min
15min
8
Hours
Pulse
2min
5min
10min
Memory
out
Clear
memory
on the IR remote
control
I am unable to set the mini
detector after installation.
The light is on and the red
indication LED is flashing
(0.25 s on and 2 s off).
The mini detector is still warming
up.
Wait 40 s. The green LED will flash
twice at short intervals once the
warm-up time has passed. Next,
the sensor can be set as normal.
I am unable to set the
mini detector. The sensor
is unresponsive. The light
remains permanently on or
off. The red LED is flashing
at regular intervals.
One of the following buttons was
pressed on the IR remote control:
•
Lock/
unlock
Short
push
Learn actual lux
20
Lux
50
Lux
100
Lux
300
Lux
400
Lux
200
Lux
500
Lux
700
Lux
1000
Lux
No
Lux
Fact.
setting
Long
push
Test
On/Off
App.
Auto
App.
Active
Light
On/Off
Memory
in
Status
Time
30min
60min
15min
8
Hours
Pulse
2min
5min
10min
Memory
out
Clear
memory
: the light remains
permanently on or off. The red
LED comes on for 0.25 s and
goes off for 10 s
• Exit the mode in one of the
following ways:
- press
Lock/
unlock
Short
push
Learn actual lux
20
Lux
50
Lux
100
Lux
300
Lux
400
Lux
200
Lux
500
Lux
700
Lux
1000
Lux
No
Lux
Fact.
setting
Long
push
Test
On/Off
App.
Auto
App.
Active
Light
On/Off
Memory
in
Status
Time
30min
60min
15min
8
Hours
Pulse
2min
5min
10min
Memory
out
Clear
memory
once
- press the connected push button
briefly
- press
Lock/
unlock
Short
push
Learn actual lux
20
Lux
50
Lux
100
Lux
300
Lux
400
Lux
200
Lux
500
Lux
700
Lux
1000
Lux
No
Lux
Fact.
setting
Long
push
Test
On/Off
App.
Auto
App.
Active
Light
On/Off
Memory
in
Status
Time
30min
60min
15min
8
Hours
Pulse
2min
5min
10min
Memory
out
Clear
memory
three times within 5 s.
•
Lock/
unlock
Short
push
Learn actual lux
20
Lux
50
Lux
100
Lux
300
Lux
400
Lux
200
Lux
500
Lux
700
Lux
1000
Lux
No
Lux
Fact.
setting
Long
push
Test
On/Off
App.
Auto
App.
Active
Light
On/Off
Memory
in
Status
Time
30min
60min
15min
8
Hours
Pulse
2min
5min
10min
Memory
out
Clear
memory
: the light remains on for 8
hours. The red LED comes on for
0.25 s and goes off for 30 s.
• Exit the mode by pressing the
Lock/
unlock
Short
push
Learn actual lux
20
Lux
50
Lux
100
Lux
300
Lux
400
Lux
200
Lux
500
Lux
700
Lux
1000
Lux
No
Lux
Fact.
setting
Long
push
Test
On/Off
App.
Auto
App.
Active
Light
On/Off
Memory
in
Status
Time
30min
60min
15min
8
Hours
Pulse
2min
5min
10min
Memory
out
Clear
memory
button once more. The red
indication LED stops flashing.
8. TECHNICAL DATA
dimensions
13.3 x 36 mm (H x W).
62.6 x 36 mm (H x W) (incl. concealed part)
power supply voltage
230 Vac ± 10%, 50 Hz
power consumption
0.2 W
relay contact
N.O. (max. 10 A), light- and motion-sensitive
Drill diameter
30 mm
maximum load
incandescent lamps (2300 W)
230 V halogen lamps (2300 W)
all low-voltage halogen lamps (500 VA)
fluorescent lamps (non-compensated) (1200 VA)
economy lamps (CFLi) (1200 VA)
maximum switching capacity
140 μF
maximum switching current
165 A/20 ms
light sensitivity
20 – 1000 lux
hysteresis on light sensitivity
+ 10%
switch-off delay
2 – 60 min.
mounting height (Fig. 3)
2 – 3 m
detection angle (Fig. 3)
360°
detection range (Fig. 3)
circular, up to 9.5 m in diameter
connected cable
50 cm, 4 x 2.08 mm²
protection degree
IP65
protection degree
class II devices
ambient temperature
-5 – +50°C
quality mark
CE marking; in compliance with EN60669-2-1
accessories
IR remote control unit (350-20090)
9. WARNINGS REGARDING INSTALLATION
-The installation should be carried out by a registered installer and in compliance with the statutory regulations.
-This manual should be presented to the user. It should be included in the electrical installation file, and it
should be passed on to any new owners. Additional copies are available on the Niko website or via the Niko
support service. The latest manual for this product is available on the Niko website at any time.
-During installation, the following should be taken into account (non-exhaustive list):
- the statutory laws, standards and regulations.
- the technology currently available at the time of installation.
- this user manual, which only states general regulations and should therefore be read within the scope of
each specific installation.
- the rules of proper workmanship.
This product complies with all of the relevant European guidelines and regulations. If applicable, you can find
the EC declaration of conformity regarding this product at www.niko.eu.
10. NIKO SUPPORT
In case of doubt or for the specific exchange procedure in case of a possible defect, contact the Niko support
service in Belgium at +32 3 778 90 80 or your wholesaler/installer. Contact details and more information can
be found at www.niko.eu under the “Help and advice” section.
11. GUARANTEE PROVISIONS
-The period of guarantee is four years from the date of delivery. The delivery date is the invoice date of purchase
of the product by the consumer. If there is no invoice, the date of production applies.
-The consumer is obliged to inform Niko in writing about the non-conformity, within two months after stating
the defect.
-In case of a non-conformity, the consumer only has the right to a product repair or replacement free of charge,
which shall be decided by Niko.
-Niko shall not be held liable for a defect or damage resulting from incorrect installation, improper or careless
use, incorrect operation, transformation of the product, maintenance that does not adhere to the maintenance
instructions or an external cause, such as damage due to moisture or overvoltage.
-The compulsory regulations of the national legislation concerning the sale of consumer goods and the
protection of the consumer in the countries where Niko sells, directly or via sister companies, subsidiaries,
chain stores, distributors, agents or permanent sales representatives, take priority over the above-mentioned
rules and regulations.
Do not dump this product with the unsorted waste. Bring it to a recognised waste collection point. Together with producers
and importers, you have an important role to play in the advancement of sorting, recycling and reusing discarded electrical
and electronic appliances. In order to finance the waste collection and processing, the government levies a recycling
contribution in some cases (included in the purchase price of this product).