10-505
22
Action
Key combination
find intercom
* 51 #
activate call forwarding
* 80 # serial number intercom # serial number internal unit for
forwarding #
activate ring-and-come-in function
* 81 # serial number intercom #
activate internal call
* 82 # serial number intercom # serial number internal unit to be
called #
activate control function for DIN rail relay
* 83 # serial number intercom #
connect intercom as slave to a master (parallel connection)
* 89 # serial number intercom # serial number master #
deactivate programming of master and slave
* 89 # serial number intercom # 0 #
5.2. Setting the ring tone
The intercom can distinguish between calls from an external unit (
door call
), a
floor call
and a call from another internal unit (
internal call
). A
separate ring tone
can be selected for
each type of call
. The device offers a selection of 13 different ring tones.
Step
Action
Result
1.
Press and hold for 8 seconds.
You will hear a beep tone and both indication LEDs will be
illuminated. The ring tone selection is activated.
2.
Press one of the following function keys several times:
• door call:
• floor call:
• internal call:
You will go through a list of ring tones available for each type of
call. The latest ring tone that you selected will be stored in the
memory of the device.
3.
Wait 8 seconds.
You will hear a beep tone and both indication LEDs will no longer
be illuminated. The ring tone selection is deactivated.
5.3. Time settings
The default time settings for the intercom are:
Parameter
Default setting
speech time from the start of the conversation
2 min
number of times the green indication LED will flash when the line is engaged
three times in 2 s
time during which the call at an external unit or a floor call remains signalled
30 s
time during which an internal call you made remains signalled
30 s
These settings can be changed via:
• the power supply (10-80X)
• the service set (10-870)
• the relay (10-83X)
Refer to the manual for device-specific instructions.
6. TROUBLESHOOTING
1. Using a multimeter, always first check the voltage between the terminals:
Between terminals …
The following voltage must be present
b and a
+ 24 Vdc
b and P
+ 24 Vdc