EN
36
10-35x
7. MOUNTING OF THE MODULES
7.1. Flush mounting module in front plate (standard)
The modules are meant for flush-mounting in front plates of the mounting sets 10-35x with a material thickness of 3 mm.
Attach the module
(1)
with the module seal
(2)
(included)
to the back of the front plate onto the welding bolts.
The protective foil can also be removed from the module
seal and stuck directly onto the module.
Attach the module using the 4 fixing nuts
(3)
(included).
2
1
3
Front plate
Image 3: Front plate ZAU
7.2. Flush mount module in front plate (special construction) so that it is adjacent at the front
To flush mount the functional module in an adjacent manner at the front, the flush-mounting depth, if the front plate is only 1.5 to 2.5 mm deep, must be increased
up to 3 mm using liners. The spacers are included with all separately ordered modules.
On the back of the front plate, place up to three spacers
(4)
on top
op each other onto the welding bolts
(5)
.
Place the module unit (2) with the cover of the front plate
(3)
.
Mount the module unit using 4 fixing nuts
(1)
.
1
2
3
4
5
Image 4: Front plate special construction