EN
34
10-10X / 10-11X(-01) / 10-12X(-01)
interchanged. This way, the programming is saved.
5. MaINtENaNCE
The following maintenance tips ensure that the surface of these products are not damaged
by improper use. Damage by improper use is not covered by the warranty.
Maintenance tips
• It is sufficient to clean the products with some soap and a damp cloth.
• You are strongly advised not to use:
- abrasive sponges or abrasive detergents.
- maintenance products containing solvents or acids or cleaning products containing
acetic acid.
- a high-pressure cleaner.
6. tECHNICaL data
power supply voltage
+ 24 V (+ 8%)
dimensions
dependent on the model (see tables
below)
operating temperature
-20 – 50°C
metal housing
aluminium, up to 7 mm thick
vandalproof nameplate
plexiglas, 5 mm thick
input current of external audio unit in rest mode
I(a) = 0.4 mA – I(P) = 10 - 26 mA
maximum input current of external audio unit
I(Pmax) = 46 mA
input current of extension module in rest mode
I(a) = 0.4 mA – I(P) = 17 - 33 mA
maximum input current of extension module
I(Pmax) = 33 mA
External audio unit dimensions
Reference code Bell push buttons
Columns of bell
push buttons
H (mm) W (mm) d (mm)
10-104
4
2
128
135
20
10-106
6
2
147
135
20
10-108
8
2
166
135
20
10-110
10
2
185
135
20
10-112
12
2
204
135
20
Other versions available upon request.