65
05-711
2. Press input 2 for 3s. The connected load first dims to the previous
set light atmosphere and after 3s to the desired light atmosphere.
You can at any time retrieve a light atmosphere by pressing input 2. To
exit the light atmosphere and switch off the load, press input 1.
With 1-button operation, you can simultaneously retrieve the light
atmospheres of different light circuits. To this end, connect terminals
2 and COM of the dimmers that control the different light circuits
(see fig.5).
After a voltage interruption the analog control will be switched on again
at the previous value.
You can connect multiple operating points with N.O. contacts (not
illuminated). You can connect a max. of 30 N.O. contacts (170-00000)
in parallel. The max. distance is 100m.
Operation of input 3 (connection terminals: COM terminal and
terminal 3):
Panic function (see 4.B)
Mode 3: ‘2’-button operation
In 2-button mode, input 1 (connection terminals, COM terminal and
terminal 1) and input 2 (connection terminals, COM terminal and
terminal 2) together function as 2-button operation (see fig.2). Input 3
allows the panic function to be activated (see 4.B).
In 2-button mode, the default setting of the analog control is with
memory function: