
62
05-711
4. OPERATION
A. Operation in the different modes
Mode 1: 0-10V analog
Operation of input 0-10V (connection terminals, COM terminal and 0-10V+
terminal):
When you select this mode, the analog control will accept a voltage
control signal from 0 to 10V in accordance with the IEC 61131-2
standard.
From 0 to 10V the light can be adjusted from 1% to max. light intensity.
The 0-10V voltage control signals are used in applications such as Silicon
Controls control systems, the Nikobus dim controller or PLC.
If the input voltage lies below the threshold voltage (+1V), the connected
load will remain switched off. If the input voltage is equal to the threshold
voltage, the connected load will be switched on at the set minimum.
If the input voltage is 10V, the connected load will be switched on at
the set max. (see fig.3). After a voltage interruption the analog control
will be switched on again at the previous value.
Operation of input 3 (connection terminals: COM terminal and
terminal 3):
Panic function (see 4.B)
EN
Summary of Contents for 05-711
Page 109: ...109 05 711 fig 1 05 711TG001 N L 230V N L N N L L 1 10V 1 10V max 30 0 170 0000X...
Page 111: ...111 05 711 N L 230V N L N N L L 1 10V 1 10V fig 3 05 711TG004...
Page 114: ...114 05 711 fig 6 05 711TG007 N L 230V N L N N L L 0 170 00000 05321 1 10V 1 10V max 30...
Page 115: ...115 05 711...