background image

If the plastic tubing on the PiMag Water System is too long, you may wish to shorten it. The following steps
are only for shortening the tubes, if you decide this is necessary. If the length of the tubes is satisfactory, skip
this section and go to Step 10 below.

Each of the 2 plastic tubes fits over a metal tube connector on the valve. Each tube is held tight to the
connector by a textured metal collar 

(

FIGURE 4

)

.

4. To shorten the tubes, first rotate each collar to loosen it.

5. Slide the collars up the tubes and pull the tubes off the diverter

valve connectors.

IMPORTANT!

One of the tubes has a molded ridge on its outer

surface. This is the tube that attaches to the input connector,
which is the upper connector on the diverter valve.

The tube without a ridge attaches to the output connector, the
lower connector on the valve.

6. To shorten the tubes, first make sure that the PiMag Water

System is positioned where you want it to remain. Then hold the
tubes against the diverter valve to see how long you want them
to be.

IMPORTANT!

If your sink has a swivel faucet, MAKE SURE

you allow enough extra length of tubing to permit the faucet to
move to the full extent of its travel.

7. When you have determined the correct length, take a knife

and carefully cut the tubes. Cut them straight across, not at an
angle 

(

FIGURE 5

)

.

8. On the tube with a ridge on it (the tube to the input connector),

carefully trim off the ridge from the final inch of tubing. Hold the
knife blade flat against the tube and be careful not to pierce it.

9. Push the tubes back onto their connectors, all the way so that

the ends of the tubes are against the diverter unit. The ridged
tube goes on the upper connector, and the smooth tube on the
lower connector. Tighten the collars all the way to provide a
secure connection.

10. Use the tube ties to secure the tubes to the faucet.

Installing the Magna-Charger

IMPORTANT!

Install the Magna-Charger on the section of

plumbing pipe that supplies cold water to the faucet. The cold
water pipe is located underneath the sink. Be sure to attach it to
the cold water pipe only.

The Magna-Charger adjusts to fit a pipe size from 0.6 inch (1.52 cm) minimum diameter, to 1.2 inch 
(3 cm) maximum diameter. For pipes smaller in diameter, rubber spacers are supplied to ensure a good fit.

11. Loosen the four screws, two on each side of the component 

(

FIGURE 6

)

.

12. Clean the section of the pipe where the component is being installed.

13. Fit the component to the pipe. If necessary, use the rubber spacers. Tighten the screws.

– 3 –

FIGURE 5.

FIGURE 6. 

Input

Output

FIGURE 4. 

Valve

Collars

Output Tube

Input Tube

Summary of Contents for PiMag

Page 1: ...NIKKEN OPERATING MANUAL MANUEL DE FONCTIONNEMENT Water System Manual Guide d utilisation du syst me d eau...

Page 2: ...ncerning the installation or operation of the water system contact your Nikken Independent Wellness Consultant The Nikken PiMag Water System is for countertop use only Do not connect the system to any...

Page 3: ...determined the correct length take a knife and carefully cut the tubes Cut them straight across not at an angle FIGURE 5 8 On the tube with a ridge on it the tube to the input connector carefully trim...

Page 4: ...tem for one minute after selecting PiMag water When the PiMag Water System is first installed use the diverter to select PiMag water and allow it to flow for five minutes This will eliminate air pocke...

Page 5: ...necessary 4 Turn on the tap and check for leaks 5 Let the water flow for three minutes to eliminate air pockets and to clear the system Troubleshooting 1 Diverter pin does not move easily or does not...

Page 6: ...etting If the water flow is still reduced the problem is not with the filters but with the household water pressure 4 Filtered water is rusty or red in color Possible cause There is a high content of...

Page 7: ...when installed Nikken warrants the parts related to the filter units of this system for 30 days from date of original purchase Parts related to the housing of the system are warranted for 1 year from...

Page 8: ...uide attentivement Si vous avez des questions concernant l installation ou le fonctionnement du syst me veuillez contacter votre distributeur ind pendant Nikken Le syst me est con u pour se raccorder...

Page 9: ...aide d un couteau FIGURE 5 8 En tenant la lame d un couteau bien plat contre la surface du tuyau muni d une ar te celui raccord au raccord d entr e tranchez l ar te sur une longueur d un pouce partir...

Page 10: ...ins une minute Apr s l installation initiale du syst me ouvrez le robinet tirez sur la tige d inversion et laissez s couler l eau pendant cinq minutes Ceci permettra d liminer l air et les particules...

Page 11: ...iez s il y a des fuites 5 Veuillez faire couler l eau durant trois minutes afin d liminer toute poche d air et nettoyer le syst me Guide de d pannage 1 La tige d inversion ne se tire pas facilement ou...

Page 12: ...e mais plut t la pression d arriv e d eau de la maison 4 La couleur de l eau filtr e est orange ou rouge Causes possibles L eau contient une forte concentration de fer soluble Solution Les filtres ne...

Page 13: ...yst me pendant 30 jours partir de la date d achat initiale Les pi ces reli es au bo tier du syst me sont garanties pendant 1 an partir de la date d achat initiale Cette garantie assure une protection...

Page 14: ...d and Certified by NSF International against ANSI NSF Standard 42 for the reduction of Taste Odor Chlorine Class I and Nominal Particulate Reduction Class I and against ANSI NSF Standard 53 for the Re...

Reviews: