X K 3 1 9 0
–
A26
()
8
Indicator display
【
bL
】
(
Power saving reminder
)
【
*
】
(
Original power saving mode
)
Now after input the new power saving mode parameter
(
0~4),press
“
clear
”
confirm
,
then press
“
Accu
”
back to weighing state.
(3)The meaning of power saving mode parameter
bL = 0
:
Close the power saving mode
bL = 1
:
Gross weight is 0 and indicator is stable for 3 minutes and indicator will
enter into power saving mode.
bL = 2
:
Display is 0 and indicator is stable for 3 minutes and indicator will enter
into power saving mode.
bL = 3
:
Indicator is stable for 3 minutes and indicator will enter into power
saving mode.
bL = 4
:
Indicator always in power saving mode .
When bL=1~3
,
any button or weight changes will cause the indicator to exit power
saving mode
10. Inner code display
(1)Enter the inner code display state.
Press"1"and"3"in the same time in weighing mode, and the indicator will enter into the
inner code display state.The bottom screen of the indicator show the indicator inner
code. 20 inner code is equal to a division.
Power saving options invalid in inner code display state.
(2)Exit
Press"1"and"3"in same time in inner code display state, the indicator will back to
weighing mode.