background image

X K 3 1 9 0 

A26 

() 

6

5. Tare operation 

(1) .Tare 

In weighing state and if the gross weight is above zero and in stable state                     

press"tare"button and delete the current gross weight as tare weight, and display the 

net weight is zero and tare indicate symbol light will on.   

(2)Cancel tare 

If the gross weight is zero or below zero and in the tare and also

 

weighing state, press

tare

can put the current gross weight to zero and the tare indicate symbol light is 

off. 

6.    Unit price input   

(1)Input 

Press 0-9 number button in weighing mode can input the unit price. 

While entering the unit price, you need to press the keys within two seconds, otherwise 

the indicator will automatically be cleared and re-start inputing. The unit price is "rmb/ 

kg", fixed to two decimal places. 

(2)Clear 

Method 1

2 seconds after unit price input

press

0

button

unit price clear to zero 

  Method 2

If the indicator not in "accu"state (accumulation indicate symbol is off),press 

clear

button

unit price clear to zero 

7. Accumulate calculate, accumulate display and accumulate clear   

(1) Accumulate calculate 

When the amount is above zero and is stable, press 

Accumulate calculate

 button , 

you can accumulate the total amount of the current amount, the cumulative number 

of times plus one, the cumulative indicate light will on. 

Indicator displays

Add    

 

Accumulated reminder, 3 seconds to return 

to weighing mode automatically 

 

               

          ** 

 

Accumulated times

up to 99 times

 

               

  ***.** 

 

Accumulated amount

up to 9999.99 RMB

 

After one time accumulated

you must return to below 50% of cumulative weight or 

re-input the unit price to the next cumulative . 

(2). Accumulative display 

When the amount is zero, press 

accumulate calculate

button, you can check the current 

accumulate times and amount . 

Summary of Contents for XK3190-A26

Page 1: ...1 XK3190 A26 Weighing Indicator U U Us s se e er r r M M Ma a an n nu u ua a al l l Version 1 01...

Page 2: ...4 Startup Zero operation and Manual zero operation 5 Tare operation 6 Unit price input 7 Accumulation clear and Accumulation display and accumulation clear 8 Saving and re call of unit price 9 Power...

Page 3: ...mV 9 Display Front side 5 5 6 digits LCD display white LED back light 4 state indication symbol 3 class battery power prompting Back side side 5 6 digits LCD display white LED back light 2 states indi...

Page 4: ...nstallation Connection 1 A26 weighing indicator front side function instruction and back side function instruction 2 1 1 Front side function instruction 2 1 2 Back side function instruction Fuse or ex...

Page 5: ...necting must be correct and reliable warning To ensure the system is working fine please fix the plug with screw to the indicator after the signal source wiring the user can not insert and pull out pl...

Page 6: ...all unit price Press two times store unit price 6 Zero button In Zero range The current gross weight as Zero Outside zero range no effect 7 On Off button Power off state Press button after 3 seconds p...

Page 7: ...will power off automatically 30 seconds later to protect the inside battery please use the indicator after charging 3 Working time A26 no back light One time charge can work around 180 hours typical...

Page 8: ...aces 2 Clear Method 1 2 seconds after unit price input press 0 button unit price clear to zero Method 2 If the indicator not in accu state accumulation indicate symbol is off press clear button unit p...

Page 9: ...dicator display SAVE unit price save reminder 0 Now press number button 0 9 to confirm the saving position indicator will be back to weighing state automatically after saving the data 2 Unit price cal...

Page 10: ...o power saving mode bL 3 Indicator is stable for 3 minutes and indicator will enter into power saving mode bL 4 Indicator always in power saving mode When bL 1 3 any button or weight changes will caus...

Page 11: ...ot 5 of the air plug on the back of the indicator is GND connect with the foot 5 of the computer 9 pin connector 3 Parameter setting Press 1 and Clear button in same time in weighing state Indicator d...

Page 12: ...to left 0 4 10 XOR checksum high 4 digit 11 XOR checksum low 4 digit 12 03 X0FF end The confirmation of higher 4 digits and lower 4 digits XOR checksum XOR checksum operated in 16 hex byte way from b...

Page 13: ...value including decimal point higher position Weighing data Weighing data 9 Weighing data low position For example the current display weight is 3 000 so the sending data is 0003 000 0003 000 0003 000...

Page 14: ...nt the weight bill After all the weighing press unit price button can print accumulate times and accumulate amount After print press accumulate clear button clear accumulate record and start the next...

Page 15: ...aper lines after every time print After enter the expected lines of run paper press the Clear button to confirm the indicator automatically returned to weighing state In the parameter input process pr...

Page 16: ...confirm and then enter to the next optional function chosen Indicator display DISP single window and three windows chosen 1 3 Now input single window 1 three windows 3 after chosen and press clear bu...

Page 17: ...ess than the setting output 3 Greater than or equal the setting and stable output 4 Less than the setting output and stable output After input the control method parameters press clear confirm Indicat...

Page 18: ...1 Examine load cell and its connecting wire 2 AD part broken please send back to factory for repairing 3 Err 08 Parameter input is not meet the requirements input parameter again 4 Err 09 Not meet the...

Page 19: ...ator damage caused by lightning strike ensure operators safety of weighing equipment and related equipment safety operation 4 Never use strong solvents e g benzene nitro class oil to clean the housing...

Page 20: ...avoid electrode in the battery being shorted and damaged 10 Since invoice date the indicator has a one year free repair period If any non artificially failure happens under regular using conditions wi...

Reviews: