E125K5 19102000
AFTER USE CARE
・
STORAGE
TROUBLESHOOTING
SPECIFICATIONS
IP CODE SUMMARY
●
●
After use, wipe off any dirt or oil from measuring surfaces, sliding
surfaces, and exterior using a dry cloth and perform rust prevention
treatment. For rust prevention, lightly apply anti-rust oil, or place in
rust preventive bag.
Store with Jaws slightly open.
If stored with Jaws closed tight, expansion due to temperature
changes may cause excessive force which will cause inaccuracy.
Store in a cool, dry, and dark location in the provided case.
Keep out of direct sunlight and moisture, and please keep secure
from unauthorized personnel.
Remove battery if Caliper will not be used for a long period of time.
●
SERVICE
●
●
If Instrument is not working properly, or if you have any questions, please contact
distributor or place of purchase.
Please note, manufacturer is unable to respond to inquires or provide service
directly. Please contact distributor or place of purchase.
INSERTING
・
REPLACING BATTERY
HOW TO USE
Before use please make the following preparations.
●
Clean off any rust inhibitor or debris from measurement and sliding surfaces.
Contamination of surfaces may cause measurement error.
●
Allow the caliper and item to be measured time to reach same temperature.
A temperature difference between the object to be measured and
the caliper may cause measurement error. Allow enough time for
the temperatures to equilibrate.
■
SET BUTTON
The SET button performs the following functions.
Press and hold for 2s.
・・・
Display is set to 0
Press and hold for 2s.
・・・
Sleep Mode
(Resume by moving Jaw or pressing any button)
③
Press and hold for 2s.
・・・
Power OFF
(Turn power ON by pressing any button two times)
■
Absolute Measurement Mode
Turn power ON by pressing any button two times.
With jaws closed, press and hold the [SET] Button for 2 sec.
When “0.00mm” is displayed on LCD, Caliper is ready to start
measurement.
■
Comparison Measure Mode
①
T urn power ON by pressing any button two times.
②
With jaws set on reference part, press and hold the [SET]
Button for 2 sec.
③
When “0.00mm” is displayed on LCD, Caliper is ready to start
measurement.
Q.
Nothing is displayed on LCD.
A.
The battery may be running low, please replace battery with
a new one.
Q.
With power on, the number on the LCD does not change as
Display Unit is moved.
A.
Please reset by removing battery for about 30sec., and then
replacing.
Q.
No response when a button is pressed.
A.
Make sure that the battery is correctly installed.
●
Use care to avoid damaging terminals when inserting battery
●
The
+
terminals may be broken if battery is pressed straight
down.
●
Insert battery at angle, with the
+
side outward as shown.
※
0.02mm higher for other than outside measurements
※
Not including quantization error (± 1 count)
0 -150
0 -200
0 -300
±0.02
±0.03
Model No.
Mass (g)
D-150IP67S
D-200IP67S
D-300IP67S
Range(mm)
※
Inst. Error(mm)
170
200
270
Batt.
Pre
sse
d D
ow
n
Batt.
+
Term.
+
Term.
Slide In
①
Unscrew the cover using the
Battery cover Tool, side marked
「
CALIPER D-***IP67S
」
②
Remove the Cover.
Insert the new battery with the
+
side outward.
Replace the cover using the Battery Cover Tool.
Use only CR2032 type battery
Notice
Battery
Cover Tool
Battery Cover
Battery
Cover
CR2032
Battery
Turn
外す
・
IP rating for electrical
equipment defined by
IEC standard for
water and solid body
protection.
1st Digit
6
2nd Digit
Description
Description
Solid Ingress
Protection
Liquid Ingress
Protection
Degree of Protection
Degree of Protection
No ingress of dust allowed.
Dust tight.
2nd Digit: Water proof rating
1st Digit: Direct contact-
protection rating for ingress
of solid foreign object
No harmful effect when
immersed in water for
specified period and pressure.
Test method
Test method
Complete protection
from dust intrusion
Submersion for 30min.
at depth of 1m (for
devices of height less
than 850mm)
7
IP67
③
④
●
Niigata Seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
+81-256-33-5522 FAX : +81-256-33-5518
MAIL:
i
URL:
http://www.niigataseiki.co.jp
①
②
①
②
③
●● Display: . . . . . . . . . . . . . . . . . . . . . . 5 Digit LCD
●●● Auto Off: . . . . . . . . . . . . . . . . . . . . .
~
20 min.
● Maximum Response
S
peed: . . . . . . 2.5m/s
● Operating Temperature Range: . . . 5°C to
40°C
●● Power: . . . . . . . . . . . . . . . . . . . . . CR2032 Lithium Battery (1x)
●● Battery Life: . . . . . . . . . . . . . . . . . . . approx. 1.5 years in normal use
●● Accessory: . . . . . . . . . . . . . . . . . . CR2032 Lithium Battery
(for test)
● Resolution: . . . . . . . . . . . . . . . . . . . 0.01mm
Battery Cover Tool