background image

 

 

2

 

IMPORTANT SAFETY INSTRUCTIONS 

 

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, 

cuts/abrasions and other hazards read all warnings and instructions included with and on the fixture box and all 

fixture labels. 

 

Before installing, servicing or performing routine maintenance upon this equipment, follow these general 

precautions. 

 

For Commercial Installation: Service and maintenance of this fixture should be performed by a qualified licensed 

electrician. 

 

For Residential Installation:  If you are unsure about the installation or maintenance of this fixture, consult a 

qualified, licensed electrician. 

   

Do not mount the unit against flammable surfaces. 

   

The motion detector will not operate correctly if it is installed: 

o

 

Near the outlet of a central heating boiler 

o

 

Near an air conditioning unit 

o

 

Pointing directly at moving vehicles 

o

 

Within sight of reflection from moving water 

o

 

Where other lamps could shine on the detector 

 

Fixtures can NOT be used with a dimmer switch, motion or occupancy sensor and other electronic switching 

devices unless otherwise designated.  LED fixtures must be powered directly off a switch circuit. 

 

Do not install more than one motion sensor light on one wall switch. 

 

This fixture should not be used in areas with limited ventilation or high ambient temperatures. 

 

This fixture is intended to be connected to a properly installed and grounded. 

 

These instructions do not claim to cover all details or variations in equipment or provide every possible 

contingency to meet in connection with the installation, operation or maintenance.  Should further information be 

needed, you may contact Customer Service at : 0345 900 6764 

 

 WARNING: RISK OF ELECTRICAL SHOCK 

 

Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply. 

 

Verify that the supply voltage is correct. Connect fixture to a 240volt, 50/60 Hz power source. 

 

Make sure all electrical and grounded connections are in accordance with the National Electrical Code and any 

applicable local code requirements. 

 

All wiring connections must be proper isolated between wire connectors. 

 

 CAUTION: RISK OF PRODUCT DAMAGE 

 

Never connect components under load. 

 

Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation. 

 

Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction 

cooling. 

 

Never connect an LED product directly to dimmer packs, occupancy sensors, timing devices or other related 

control device, unless individual product specifications deem otherwise.  

 

Unless individual product deems otherwise: do not exceed fixtures maximum ambient temperatures.  

 

LED products are Polarity Sensitive.  Ensure proper polarity before installation. 

 

Electrostatic Discharge (ESD) can cause damage to LED fixtures.  Personal grounding equipment must be worn 

during all installation or servicing of the unit. 

 

Do not touch the individual electronic components, it may cause ESD, shorten lamp life or alter performance. 

 CAUTION: RISK OF INJURY 

 

Wear gloves and safety glasses at all times when removing fixture from carton, installing, servicing or performing 

maintenance. 

 

Avoid direct eye exposure to the light source while it is on.   LED LAMPS ARE EXTREMELY BRIGHT. UNDER NO 

CIRCUMSTANCES SHOULD YOU STARE INTO AN LED BEAM, THIS MAY CAUSE IRREPARABLE DAMAGE TO THE 

EYE. 

 

Account for small parts and destroy packaging materials, as these may be hazardous to children 

 WARNING: RISK OF BURN 

 

Allow fixture to cool before handling.  Do not touch enclosure of light source. 

 

Do not exceed the maximum wattage marked on the label. 

 

Keep combustible and other materials that can burn away from the luminaries, fixture and lamp/lens. 

 

Summary of Contents for NW16TSP

Page 1: ... read these instructions carefully prior to installation and retain them for future reference Failure to follow any of these instructions could void product warranties 0345 900 6764 www nightwatcher co uk support centre NW16TSP ...

Page 2: ... circuit breaker box before wiring fixture to the power supply Verify that the supply voltage is correct Connect fixture to a 240volt 50 60 Hz power source Make sure all electrical and grounded connections are in accordance with the National Electrical Code and any applicable local code requirements All wiring connections must be proper isolated between wire connectors CAUTION RISK OF PRODUCT DAMA...

Page 3: ...s Install the motion sensor 6 5 ft 1 9 m 10 ft 3 m above the ground Motion sensor is less sensitive above 10 ft 3 m Mount motion sensor so motion moves across detection zone Mount sensor away from heat producing sources to prevent false triggering Also be very careful not to include objects such as windows white walls and water in the detection zone Mount fixture away from moving objects such as t...

Page 4: ...G LIST Part Description Quantity A Screw Hole Silicon cover 1 B M4 X 56mm Center Screw 1 C Drywall screw 2 D Light Back Cover Plate 1 E Plastic Masonry Plug 2 User Manual 1 Mounting Hardware included Tools Required for Installation Not included ...

Page 5: ...ic shock Disconnect power at fuse or circuit breaker before installing or servicing CAUTION Do not cut any wires with factory installed wire connectors or remove the wire connectors Step 2 Wiring the Light Fixture Connect the light wires inside the connection block The mains wire should pass through the Plastic Cover Bracket D Neutral Blue to Neutral Blue Earth Green to Earth Green Yellow Live Bro...

Page 6: ...t Fixture screw hole with A the Decorative Silicon Cover Note Make sure all the wires are properly connected inside the connection block before attaching the light to the wall Step 4 Caulking Around the Light Fixture Caulking Around the Light Fixture For additional protection caulk around the joint between the light fixture and mounting bracket using a silicon sealant not included ...

Page 7: ...ction Adjust the lamp head direction by moving up and down Note LED LAMPS ARE NON REPLACEABLE Do not attempt to access maintain the LEDs they are non replaceable and any contact may damage the LEDs and will void the warranty 2 The Motion Sensor Detector Detection Range 49 2 ft 15 M 220 degrees on an optimum installation height of 2 5 meters Note When you first install your security light ensure th...

Page 8: ...15M Dusk Level Ambient Light LUX Setting This setting is used to control the ambient light level for the motion security light to turn on You can set the light to turn on only in the darkness by turning the LUX setting to counter clockwise position Or allow the security light to trigger even during daylight by turning the LUX setting to full clockwise or at ambient light level in between NB LED LA...

Page 9: ...and with NOT be controlled by time duration or ambient light LUX levels The MANUAL MODE will change to AUTO MODE in 6 hours automatically During MANUAL MODE by switching the main switch OFF then back ON again the PIR sensor will reset the warm up period and then AUTO MODE SPECIFICATIONS 1 Detection Method Passive Infrared Sensor PIR 2 Sensor Range 2M 15M x 220 degree spread approx 3 Time Adjustmen...