Height Rider/SP Series
Operating & Safety Instructions
English/USA – 07/17
Original instructions
29
4.3.3
INFORMATION ICONS
Safety Critical (Main screen)
MAX tilt angle exceeded:-
The alarm sounds, the display shows this
image and drive is disabled. Lower booms down into the stowed position
and drive onto level ground to fully restore machine operation.
Safe Working Load (SWL) exceeded:-
The alarm sounds and the display
will show this image. The Maximum SWL (250kg/550lbs) has been
exceeded. Immediately remove any unnecessary items from the platform
in a safe manner
to restore machine functions.
Alternatively, the platform may have come into contact with a fixed object,
see Section 4.3.5 for recovery procedure.
Note: If a
Safety Critical
condition has been detected, the safety warning
lamp on the Platform Control Panel and Base Control Panel will also
illuminate.
Advisory (Main screen)
Release E-Stop:-
Machine will not operate as one or both of the
Emergency Stop buttons are pressed. Twist and release to restore normal
controls.
Footswitch Timeout:-
Machine will not operate. Release and re-press
footswitch or green button to restore normal controls (Refer to Section
4.3.1).
Controls Neutral:-
Boom control paddle or drive joystick has moved from
the neutral position
before
the green button or footswitch was pressed.
Return to neutral position and move
after
green button or footswitch has
been pressed (Refer to Section 4.3.1).
Joystick Timeout:-
Machine drive will not operate.
Release and re-press
trigger to restore normal controls (Refer to Section 4.3.1).
Fuel Level Low:
Flashing fuel pump icon indicates fuel tank is <10% full.
Amber level indicates fuel tank is <30% full.