52
Error Code
Description
Action
01E30000
There is a problem with the signal
from the Slew Paddle in the cage
Return the Slew Paddle to neutral and attempt to operate
Slew again.
Check the connector to the Slew Paddle is secure.
Replace the Slew Paddle
01E50000
There is a problem with the signal
from the Telescope Paddle in the
cage
Return the Telescope Paddle to neutral and attempt to
operate Telescope again.
Check the connector to the Telescope Paddle is secure.
Replace the Telescope Paddle
01E60000
There is a problem with the signal
from the Drive Joystick in the cage
Return the Drive Joystick to neutral and attempt to
operate the Joystick again.
Check the connector to the Drive Joystick is secure.
Replace the Drive Joystick
01F20000
A software parameter is missing
or not valid
Cycle the power to the machine
01F30000
The serial number of the machine
is incorrect
Check the machine serial plate.
Contact a Niftylift approved service centre
01F40000
The PLC is set to download
Move the Test Jumper in the Main Control Box to 0 V
(Zero volts)