SD Series
Operating & Safety Instructions
USA 03/12
23
EMERGENCY PROCEDURES
1)
Push in red emergency stop to shut down all functions.
2)
Use manual hand pump to manoeuvre machine into a safe place. Base or basket controls can
be used whilst the hand pump is being operated. Only when the machine is fully stowed should
the flow be directed to the jack controls in order to recover the jacks. Failure to follow this
procedure could result in serious injury or risk of death.
4.3.2
BOOM FUNCTIONS
A)
Push and hold green power button.
1
2
3
4
B)
Select lever 1, 2, 3, or 4 for desired boom function.
1
Operates Telescope
UP
for out
DOWN
for in
2
Operates Lower Boom
UP
for up
DOWN
for down
3
Operates Upper Boom
UP
for up
DOWN
for down
4
Operates Swing
UP
for right
DOWN
for left
ALWAYS ENSURE THE NIFTYLIFT IS ON A FIRM SURFACE AND THE AREA IS
FREE OF ANY OVERHEAD OBSTRUCTIONS.
ENGAGING THE RED EMERGENCY STOP BUTTON WILL SHUT DOWN THE
ENGINE, AND THE ELECTRIC CIRCUIT PREVENTING OPERATION OF ANY
FUNCTION.