Advice before Use 

 

Read this instruction carefully.                      

 

As soon as the equipment is delivered, open the packing and inspect the equipment carefully. If you notice any 

damage, contact the transport company immediately and register your complaint in due form listing the defects.                              

 

We can assure you, that this equipment left our factory in perfect condition. 

 

Check it the received equipment is consistent with the delivery notice and if the delivery notice is consistent with your 

order. If it is not, immediately contact your supplier.        

 

General Remarks 

This luminaire is lighting equipment designed for professional indoor use in theaters and televison- or film studios. 

Designed and build in accordance with EN 60950 and EN 60598-17 regulations, it must imperatively be connected to earth 

by means of its earth wire.  

To prevent any electrical shock, this equipment should not be opened when it is powered.                                        

Nevertheless: 

 

Any parts or lenses need to be replaced if they are visibly damaged and their efficiency might be reduced, e.g. in case 

of deep cracks or scratches.                            

 

The lamp must be changed if damaged or distorted by heat.                                                   

If internal access is needed for control, service or repair purposes, always refer to qualified personnel. Always be sure to 

unplug the power supply cable before opening the fixture. 

 

ATENTION: LETHAL VOLTAGE PRESENT INSIDE !        

                                

It is the user responsibility to use the luminaire for intended purpose and to check the equipment that might be connected 
to it.                            
The luminaire can under no circumstances be modified. Niethammer Lichttechnik GmbH will not assume any responsibility 
in case of damage resulting from modifications made to the luminaire.                  
This luminaire is a piece of professional equipment designed for easy and simple use. Always refer to qualified personnel for 
any using, installation or repair work.                                              

Avoid installing the luminaire near inflammable matters. Minimum distance between luminaire and inflammable matters is 1,9m

.                                   

 
Important Remark: 

Power supply cables and other connections are essential for your equipment and contribute greatly to a safe and trouble 

free operation. 

 

Always pull the plug when disconnecting a cable, never pull the cable.                  

 

Never use cables and connectors in bad conditions, check them before installation and periodically thereafter                                                                                                              

 

Never tie power supply and data cables together.                 

Summary of Contents for HPZ 112 D

Page 1: ...NIETHAMMER HPZ 112 D and HPZ 115 D Niethammer HPZ 112 D and HPZ 115 D Page 1 Instruction Manual HPZ 112 D HPZ 115 D E112 115 201301 ...

Page 2: ... case of deep cracks or scratches The lamp must be changed if damaged or distorted by heat If internal access is needed for control service or repair purposes always refer to qualified personnel Always be sure to unplug the power supply cable before opening the fixture ATENTION LETHAL VOLTAGE PRESENT INSIDE It is the user responsibility to use the luminaire for intended purpose and to check the eq...

Page 3: ...12 has five fixing holes 4x11mm 1x13mm diameter 1 Lamp Housing 2 Rear section Screw 3 Accessory slot 4 Beam Shaper 5 Iris 6 Friction point 180 7 Focus 8 Front lenses tube 9 Filter Frame Holder 10 Zoom 11 Tilt locking handle 12 Yoke 13 Friction adjustment Lamp housing 14 Handle This luminaire can be suspended from a barrel by a hook clamp it can also be mounted on a stand ...

Page 4: ...s for 1000W Lamp position near the mirror is for 1200W No more modifications are needed All other parts are fixed in the lamp housing Parts of Optical System The plane of projection you can find between lamp housing 1 and the front lenses tube 8 Here you can find the Iris 5 the Accessory slot 3 and the beam shaper 4 To put the Iris in and out you must remove the small plastic bolt With the Iris it...

Page 5: ...ouch the optical parts bare handed The mirror and the aspheric lenses must be changed every 2 to 3 years to guarantee a maximum light output To clean the zoom lenses please open the door of the front lenses tube 2 screws 2 For the Iris please don t use fat or oil 3 Please check frequently all electrical cables electrical and mechanical parts of the luminaire Tighten the screws if needed If you are...

Page 6: ...NIETHAMMER HPZ 112 D and HPZ 115 D Niethammer HPZ 112 D and HPZ 115 D Page 6 Optical System HPZ 112 D HPZ 115 D ...

Page 7: ...NIETHAMMER HPZ 112 D and HPZ 115 D Niethammer HPZ 112 D and HPZ 115 D Page 7 ...

Page 8: ... Find more information about spareparts on our webpage www emil niethammer de Spareparts for HPZ 112D Standard Spareparts for HPZ 115D Standard Niethammer Lichttechnik GmbH Hintergasse 30 D 61239 Ober Mörlen Tel 00496002 93 933 0 Fax 00496002 93 933 33 info emil niethammer de www emil niethammer de ...

Reviews: